    Easy Touch Programming VSF

    By High speed, I mean fast enough to move the water for skimming. Seems like not much circulation until I get up to higher speeds. Maybe I should shut off main drain.
  2. D

    Easy Touch Programming VSF

    Well as I stated am brand new to pools. Thought that some water circulating was better than none. My Chlorinator needs at least 15. Heater probably best to go about 40. So if I want to run my pump 16 hours per day, should just find RPMs to do just above 15 GPM and then when calling for heat...
  3. D

    Easy Touch Programming VSF

    Thanks. So you wouldn't run your pump overnight below the flow level for your chlorinator? The program you are using looks different than mine. Is that the one developed for PBs as opposed to consumers?
  4. D

    Easy Touch Programming VSF

    For some reason I can't figure out how to program the easytouch to properly control my Intelliflo VSF. It seems like a pump gets attached to a circuit, but I can't figure out how to schedule the circuit multiple times with different flow rates. I want to do something simple like run the pump 9...
  5. D

    Start up Guide

    Equipment operation. I assume I get it circulating first, then deal with the chemistry.
  6. D

    Start up Guide

    I have read every manual I have, hundreds of hours of documentation about building a pool, but you are right I have not read about how to open the pool up; thats why I am soliciting a good resource to read :)
  7. D

    Start up Guide

    Is there any good pool startup guide anywhere. I have spent the last 4 months building my pool and I have everything hooked up, but need to build up the guts to start it all up I have a cartridge filter, heater and SWG as well. I suspect all i need to do it prime the pump and turn it on, dump...
  8. D

    Pentair SWG

    Yes, there are 4 wires from each. I am not sure if they are the same 4 wires. It looks like the sub-board might use full duplex RS-485 and the port to SWG uses half duplex RS-485 and the AC power on other 2 connectors.
  9. D

    Pentair SWG

    Yes there is a 4W running from the SWG board to the main board and I do have the connector on the bottom of the LV raceway. Sounds like I am golden. Good to hear and much thanks.
  10. D

    Pentair SWG

    Hi, I do have the big transformer and the circuit board. Mine is soldered to J7 vs molex connector but otherwise the same. Now knowing this board is for the intellichlor, and seeing there are 2 power and 2 data connections, I think this may have answered my question but happy to hear your...
  11. D

    Pentair SWG

    I now have my new Intellichlor. I have hooked up the primary transformer in the Easytouch Load Centre to the filter/pump relay output (both legs of the 240V to the relay output and input to both sides of a 240V breaker). The manuals (both Easytouch and Intellichlor) are really unclear on the...
  12. D

    Pentair SWG

    Jim, thanks this was the definitive answer I was looking for. My Easytouch did not come with a cell for whatever reason.
  13. D

    Pentair SWG

    Thanks for that advice. I filled in my sig. I have a 14k gallon pool; so maybe I should just forget about the IC15, return it and buy an IC40.
  14. D

    Pentair SWG

    Hi, I have an EasyTouch 4P-C (which I think is the Canadian version.) It has the option for the Intellichlor and there is a transformer for it inside the high voltage compartment and a connector on the bottom left of the unit. I looked at the power cable coming off of the Intellichlor and...
  15. D

    Pentair SWG

    Hopefully someone on here understands the Pentair line well. I have an IC15 and it is unclear in the documentation whether I can hook this up to my Easytouch controller and the associated transformer in the Intellicenter. Does anyone know whether IC15 is compatible with the Easytouch?