    SCG (IC60) is tripping the breaker

    I purchased a QHHR brand load board from Amazon for $80. It fixed the problem. It's been working for 2 weeks. The J9 connector is bigger than on the original board so I had to cut and crimp a new connector to one of the wires. The old board may be repairable. It appears that the bridge...
  2. D

    SCG (IC60) is tripping the breaker

    The breaker is tripping for the SCG on my Pentair Intellicenter System. The breaker trips with the cell disconnected and I've replace the breaker. I assume the problem is the SCG Load Center Surge Board. My part number is 521593. Questions: 1. Is the board repairable? Is there a schematic...
  3. D

    SWG cell location

    Great, thanks
  4. D

    SWG cell location

    Does it matter if the salt generator cell is placed before or after the pool heater? Does the cell output affect the heater or does the warmer water affect the cell? I'm installing a new Pentair IC60 cell and a new Pentair Master Temp heater.