    IC40 displaying good flow/salt levels no chlorine production

    Just completed rewiring the surge panel to the J20 and everything works now! Thanks to all for the inputs -- there was some electrical tape on the connections that had melted from the afternoon sun. Clean connections for the J20 did the trick. I appreciate everyones help with this!
  2. D

    IC40 displaying good flow/salt levels no chlorine production

    I have checked the panel and it looks connection is from J20 to the com3 port on the surge card. It's quite a jumble at J20 with the pump, surge connection, and wireless module connected there. Everything looks solid - would you recommend removing the connections and redoing the wiring? I've...
  3. D

    IC40 displaying good flow/salt levels no chlorine production

    I have a whisperflo vs pump, the IC is the only connection on the comm link far as I know. Still under warranty far as I know so hopefully a replacement is an option if nothing else checks out.
  4. D

    IC40 displaying good flow/salt levels no chlorine production

    Allen, Thank you for your post -- cell percentage is at 100 but I am only able to verify this value after depressing/holding "less" on the IC for a brief time. This results in the display showing the current assigned value. Once these lights have greened up, I am able to adjust the value...
  5. D

    IC40 displaying good flow/salt levels no chlorine production

    Hello, I've read through several related threads and attempted to troubleshoot my Pentair SWG on my own without any luck. Maybe someone can figure out what I missed! First a little overview and then I'll list the troubleshooting I've done: IC40 purchased/installed last May (2021) worked fine...