Recent content by dandannoodles

  1. D

    Leak in Pentair Microbrite LED fitting

    I'm in Orange County. Super nice of you to offer. At the moment, I'm in touch with Pentair and they sent me a form to fill out, which will put my products under warranty. Assuming I can get some info from my pool builder, Pentair said they can submit a work order and have someone come out and do...
  2. D

    Leak in Pentair Microbrite LED fitting

    I've been going through CYA and salt like crazy. And the chlorinator is cranked up. So looks like I just need to buy an o-ring, the removal tool and silicone lube...
  3. D

    Leak in Pentair Microbrite LED fitting

    Yep, I saw this. So looks like it's ok not to have a flooded conduit? Assuming I follow these instructions? Ok to do this underwater?
  4. D

    Leak in Pentair Microbrite LED fitting

    My pool is leaking! I isolated the leak to one of the Microbrite LEDs, as it connects to the fitting. Here's a video: https://photos.app.goo.gl/7CGBYDLJuhfa6JiR6 My pool builder is ducking me so I'm just going to fix this myself. I assume I need to buy the installation tool (I don't think I...
  5. D

    FOUND THE LEAK!!!!! (spoiler, it was one of the nicheless LED lights)

    I don't look forward to digging up the conduit. What is the best solution?
  6. D

    FOUND THE LEAK!!!!! (spoiler, it was one of the nicheless LED lights)

    I have. he said he can come by next Wednesday. But I want to know what the fix is or how you guys would handle it. Not that I don't trust him...
  7. D

    FOUND THE LEAK!!!!! (spoiler, it was one of the nicheless LED lights)

    A year after finishing the pool build, I finally located the leak. Hoping the repair is easy. Long story short, we finished building the pool last summer and were very happy to start using it. I quickly realized I was losing salt very quickly. Something like 100 PPM a week. CYA was also...
  8. D

    Pool Mode and Spa Mode and... in between mode?

    So we don't really use the spa like an actual spa. We have little kids and they complain the pool is too cold, so I heat the spa up to like 85 degrees. I don't really mind getting the pool warmer either? It's actually nice, since we have some heated water going to the spa and then some going to...
  9. D

    Pool Mode and Spa Mode and... in between mode?

    Yes, I have an IC40 plumbed immediately before the Intellivalve at the return side. I do have it set to generate chlorine when in spa mode, but at a much lower level.
  10. D

    Pool Mode and Spa Mode and... in between mode?

    We've been using the pool a few weeks now and I'm dealing with things I would like guidance on. Details are as follows: The pool is plumbed in such a way that even in pool mode, some water is returned to the spa and over time, there is a slight overflow sending water from the spa into the pool...
  11. D

    Lost 900ppm salt and 25ppm CYA in a little over a month of heavy swimming

    Also, one other question. Is it possible that it's not algae and it's just a bunch of organic contaminants? I've been getting lots of leaves and bugs in the pool lately... could that be eating up the chlorine?
  12. D

    Lost 900ppm salt and 25ppm CYA in a little over a month of heavy swimming

    I'll do the OCLT test and report back. Yes, salt and CYA dropped dramatically in the last month. CYA was 70 on July 5, 45 on Aug 7th. I know it's a lot but we've been using the pool a lot... 4 kids in it daily, then with friends over its like 8 kids splashing around and using the pool to fill...
  13. D

    Lost 900ppm salt and 25ppm CYA in a little over a month of heavy swimming

    To clarify, I used a salt test to confirm I went from about 3900 ppm to 2800 ppm. My SWG was saying the same thing over the last few weeks, but I confirmed with the actual test. My FC was going up initially, going from 4-5 to 10 in less than a week. This is when I turned it down. I turned it...
  14. D

    Lost 900ppm salt and 25ppm CYA in a little over a month of heavy swimming

    I'm nearly certain I don't have a leak and I didn't backwash during this time... so I am chalking it up to splash out and heavy use, but wanted to see what you guys thought. July 4th my CYA was at 70 and salt was 3800. It's a brand new pool and that was my baseline to have it ready for swimming...