Recent content by cvacd5

  1. C

    Installed upgrade Aqualink IQ-30 RS Antenna & PCB- Pump Won't Turn On

    It was a $16 circuit breaker!!!! Everything is up and running!!! Thanks for the great help! This board is a life saver! Thank you thank you thank you!! If you are in central Texas, I owe you a lot of beer!!
  2. C

    Installed upgrade Aqualink IQ-30 RS Antenna & PCB- Pump Won't Turn On

    Son of a nutcracker!!! It is the circuit breaker I bet!!! After the freeze and when I noticed the pump was off I went to the breaker and it was tripped. I never actually tested the voltage at the breaker, just used the volt pen to see there was power coming from it and not knowing, if I was...
  3. C

    Installed upgrade Aqualink IQ-30 RS Antenna & PCB- Pump Won't Turn On

    Ok so tested at the pump, when putting on each line together I get .05 but when I do ground wire and L1 or L2 I get 125 on each line. So that can rule out the bad motor correct?
  4. C

    Installed upgrade Aqualink IQ-30 RS Antenna & PCB- Pump Won't Turn On

    I purchased it from a pool service company who had it installed one day but had to replace it because it is a pool only board and they needed the pool & spa one. So I erased the memory and set it up for the SP pump, wasn't listed as an option in iaqualink but I could set it as just a filter...
  5. C

    Installed upgrade Aqualink IQ-30 RS Antenna & PCB- Pump Won't Turn On

    Hi! Hoping one of y'all can save my day here. So I had an old system Aqualink with PDA and contacted Jandy because my pump would not turn on anymore and they informed me that the only upgrade possible to do would be the IQ-30 RS, which I purchased and installed. I replaced the pump with a new...
  6. C

    Is it odd that my unground pool has a plug in light set to a timer?

    Hi! Is it odd that my pool has a 120v plug in pentair pool light and not wired to the Aquasource control box? I need to change it out and want to make sure I am not going crazy here.