Recent content by chpthrll

  1. C

    goldline Aqualogic ps8 aux switch problem

    I'll try that,just can't figure out why the relay is not responding to button push!
  2. C

    goldline Aqualogic ps8 aux switch problem

    there's no group function that I can find, also the aux switch does not work, no clicking when selected yes this is new event
  3. C

    goldline Aqualogic ps8 aux switch problem

    Had this system for maybe 8 years, had all the regular problems with the pcb and did most of the servicing myself.Now when I switch on the super chlorinator the aux switch 4 turns on also, which turns on lights around pool.I just can't figure out how this can happen. Any thoughts would be a...
  4. C

    Pentair SD80 sand filter leak

    I have called Pentair and started a case,will keep updating here,wish me luck!
  5. C

    Pentair SD80 sand filter leak

    Just found my sand filter leaking and after checking all the connections found the leak coming from the bottom.After vaccuming all the sand out and removing the shell found the bottom seam pulled apart!! Anyone ever seen this or have any idea what could cause this??
  6. C

    Aqua Logic Salt Too High - Cholrinator Off High Salt/Amps

    Just repaired mine as well. A few years ago had the same problem,but needed a board that would support the Aqua Pod,so never repaired it!! Was wondering if the firmware can be updated on these boards Thanks for everyone for the good work!
  7. C

    Aqua Logic Dimmer AQL_DIM

    I have an Aqua Logic PS-8 that i would like to add a dimmer(AQL_DIM).There are 4 lugs on the original light switch and 4 on the dimmer. The orig switch only had 2 wires on the first two connectors and works just fine,however when i installed the dimmer nothing happens at all.And yes i did...