    Aqua Logic Salt Too High - Cholrinator Off High Salt/Amps

    Re: Aqua Logic Salt Too High - Cholrinator Off High Salt/Amp I got the error back after the tech soldered the K1 relay a few weeks ago. I'll check the fuse before calling the pool co back out. This is really frustrating!
  2. C

    Aqua Logic Salt Too High - Cholrinator Off High Salt/Amps

    Re: Aqua Logic Salt Too High - Cholrinator Off High Salt/Amp And yet another victory for soldering the K1 relay by a pool tech that knew what he was doing and fixed it without a 2nd thought. In fact, he went right to it and was surprised when I asked if that's what he was doing. My old salt...
  3. C

    Hello from AZ

    I've been cleaning the filters and salt cell properly every 3 months for the past 4 years,. Yes, I learned how on Youtube. I test the water every other day (if not more often) and clean the skimmer and drain baskets weekly, so I'm pretty sure the water is clean and sanitary. No green pool for...
  4. C

    Hello from AZ

    Thanks for the welcome. I'm learning how to take care of the pool and not making as much headway as I'd like to. I have a high salt/amps reading so looked it up and found the idea of soldering the K1, but dang if I can't even find it. I got brave enough to take the control box apart and look at...
  5. C

    Hello from AZ

    Introducing myself as a new member. I have a 10K gallon salt pool, pebble tech finish, Hayward filter, and Aqua Logic control board. The company that built my pool is no longer in business, so I seek information and help online when I have a problem, which lately is a lot. Looking forward to...