Recent content by CAPool233

  1. C

    Intelliflo Vsf not working

    Thank you for your help. I ended up calling Pentair and learned that the intelliflo vsf pump needs to be updated and they have arranged for a pool company to come update the pump since it is under warranty.
  2. C

    Intelliflo Vsf not working

    After several days of working perfectly, The EasyTouch has lost communication with the intelliflo vsf pump. I have tried controlling lights from ScreenLogic and that is working fine. I have checked connections and all seem to be fine. Any ideas
  3. C

    Intelliflo Vsf not working

    Thank you for your reply. I did find the 240 wires from motor on the load side and moved them to the line side but the Wi-Fi to system had to be reset also has nothing was working from the app. As of last Thursday everything appears to be working fine
  4. C

    Intelliflo Vsf not working

    I was getting the power outage and lost communication messages. After checking this forum and talking to Pentair I moved the load wires to the line side terminals on the relay. However, the pump does not seem to be working and my Pentair app is still displaying the error messages. Any advice?