Recent content by BrianMars

  1. BrianMars

    Help - Can I Swap Out My Multiport Valve Myself?

    Well I figured out what the leak around the handle was - there was a little O-ring on the post that the handle connects to that had deteriorated. Replaced that and no more leak from the handle. At least now I can run the filter until the new valve gets here. My Hayward valve is the kind that...
  2. BrianMars

    Help - Can I Swap Out My Multiport Valve Myself?

    So I've been having problems with my Hayward SP0710X32 valve, which is probably 15 years old. It was leaking out the waste line, so I figured I'd replace the spider gasket, but I found several of the internal plastic walls/diverters are warped, and one is cracked where it holds the gasket. I...
  3. BrianMars

    What's your current pool temp?

    We were running about 84/85 in the pool with outside temps being about 86 on the 4th. Air movement was low, so spent a good portion of the day with kids and a couple friends in the pool and working the grill.
  4. BrianMars

    pool games

    Tag with foam nerf balls.
  5. BrianMars

    Main Drain - to Use or Not?

    Thanks - I guess some people like the option of having them, my buddy has a 20 x 40 with no main drain at all and it's fine. My water is also crystal clear since I switched to liquid chlorine (thanks to the TFP site!) and my chemicals are largely staying in balance. I just wanted to be sure it...
  6. BrianMars

    Main Drain - to Use or Not?

    Hi - this is our second season in our new house with our in-ground 16 x 32 pool, and I have a question about using or not using the main drain on the pool. The pool has a shallow end of 3 foot down to the deep end of 8 feet where the drain is. Per the previous owner, he says he used the main...
  7. BrianMars

    In Ground Pool Leak Just Discovered This Weekend

    Richard - I checked the backwash/drain pipe while the pump was running in filter mode last night and sure enough, a steady stream of water came out of it when I disconnected it from the waste fixture. When I shut the pump off and adjusted the valve, I got it to stop leaking while in filter mode...
  8. BrianMars

    Inground Pool Leak

    Unfortunately I have to agree with Jim, I'm a new pool owner (second year in house that had one when I bought it) and by my estimation, I'm losing 1/2 inch over a 6-7 hour span when I run the pump which loosely calculated is 120 - 150 gallons for my 16 x 32. I have a leak in my Hayward pump...
  9. BrianMars

    In Ground Pool Leak Just Discovered This Weekend

    Thank you for the reply and the gallon estimate - and that's what I was afraid of.:( Yes, the waste line is hard plumbed to the sewage line. But it's an opaque hose so I can't see if water is running or not. I suppose I could disconnect where the waste hose connects to the plumbing (it's right...
  10. BrianMars

    Inground Pool Leak

    Hi qdylan - I feel for you, I too have a similar problem with my 16 x 32 pool, sorry I don't have good answers for you right now. I did post my experience today and I hope it is due to the leaky seal on my Hayward pump, but I don't know if that's the sole source or not. Hoping you find your...
  11. BrianMars

    In Ground Pool Leak Just Discovered This Weekend

    Hi - Looking for some advice, please. I am a second-year owner of a house with a 16 x 32 in-ground pool, 3ft shallow to 7ft deep end. Hayward Sand Filter and Hayward Super Pump 1HP. All equipment is 10+ years old, came with the pool. Filter was inspected and cleaned. Pump ran fine last season...
  12. IMG_5612.JPG

    IMG_5612.JPG

  13. IMG_5600.JPG

    IMG_5600.JPG

  14. IMG_5593.JPG

    IMG_5593.JPG