Recent content by Bob Jakob

  1. Bob Jakob

    Hayward S3 Omni/TCELLS340 (T-15, right?) issues with generation

    Between 50 and 60 °F the cell production is reduced to 20%. Under 50°F the cell will not produce, it will shut down.
  2. Bob Jakob

    Warped baffle

    Have actually done this with cell in stand and filled with salt water to test cell construction. If left long enough the water will actually boil off.
  3. Bob Jakob

    Warped baffle

    The cell is actually running when there is no floe. It will get hot enough to boil all the water out of the cell. It will not explode if the valves are open so the pressure can be released into the pool. The cell should not by powered when there is no flow. This is not a product defect; it is an...
  4. Bob Jakob

    Direction does matter when installing a T-Cell

    I would think that the preferred orientation would be hump down and cord first to not have the cell reactions influence the temperature probe.
  5. Bob Jakob

    Strange Salt Cell Issue

    What flow rate are you running? If the blades are not fully wetted the salt calculations will not be correct.
  6. Bob Jakob

    New Hayward Aqua-rite T-3 cell displaying too much salt.

    Make sure Aquarite is set to T-3 Cell. Incorrect cell choice will give higher salt concentration.
  7. Bob Jakob

    SWG % Output/Chlorination Cycle - Aquarite S3

    The AquaRite S3 produces continuous chlorine at a percentage of maximum production. This is changed from the earlier Aquarite systems that produced maximum chlorine on a time basis.
  8. Bob Jakob

    Anyone had trouble with Salt Solutions replacement cells lately?

    Generic cells produce generic results. Buyer beware.
  9. Bob Jakob

    Hayward Aqua rite reading HIGH salt level

    Your salt level is probably high. Store test results are not known for accuracy.
  10. Bob Jakob

    Hayward SWG - Salt reading problem

    Amperage is indicating that the salt is probably in the 2100- 2400 ppm range. Store results are always suspect. Get yourself a proper test kit.
  11. Bob Jakob

    Aftermarket SWG???

    Generic cells produce generic results. Buyer beware.
  12. Bob Jakob

    Non-Hayward brand replacement for a Hayward T-cell 15

    Generic cells produce generic results. Buyer beware.
  13. Bob Jakob

    Hayward aquarite AQR15

    How are you testing salt?
  14. Bob Jakob

    1st opening with swg

    Test strips are never accurate, they have many interferences that produce erroneous results. Digital salt testers can be accurate but need to be constantly calibrated with known reference solutions.