Recent content by bigred

  1. B

    Contactor chattering noise

    Sorry for the delay in answering all the questions. I was able to get a brand new older style top side controller and that fixed the problem. No more chattering contactors. It is a brass thermostat and not a newer digital one so not as accurate but does the job. Basically should have done a top...
  2. B

    Contactor chattering noise

    no, I was jumping the violet and violet/white wire at the block plug and it was calling for heat. When the new controller is plugged in and the dial is turned up it does not call for heat.
  3. wiring diagram.jpg

    wiring diagram.jpg

  4. B

    Contactor chattering noise

    update: I ordered the new topside controller and it plugs right into the side of the Brett Aqualine pack just fine. It still does not call for heat when the dial is turned up. With the topside controller unplugged from the spa pack, I can jumper the two female plug sockets (violet and...
  5. B

    Contactor chattering noise

    Fair enough. Thanks. I ordered pressure switch today and will see if that takes care of it. We are starting out simple. If that doesn't do it then I will head to the temp sensor (thermostat). I will start pricing out a top side controller. Prob should replace it anyway before it is discontinued...
  6. B

    Contactor chattering noise

    Nobody wants to take a stab at this? Come on somebody say something.... I pretty much think it needs a new pressure switch. Plus a thermostat which is hooked to the topside controller which leads me to the replacement of the Tecmark 2 button controller.
  7. B

    Contactor chattering noise

    I have a Great Lakes hot tub with a Brett Aqualine spa pack in it. I have replaced both contactors and both relays. When it calls for heat it will hang up between calling for heat and not calling for heat making this awful contactor chatter noise. If you turn the dial higher or lower when it...
  8. B

    Hayward heater H100IDI

    no ignitor available locally so I put the old one back in. no fuse on the circuit board either. the guy asked me why i was replacing it so i told him the deal and he thought once it lights it is done becasue it has done its job. he did not think it was flame sensor of any kind. does this...
  9. B

    Hayward heater H100IDI

    didn't know that about the ignitor. maybe I can purchase a new one locally and see if that does it. I thought because it ignites the ignitor was fine. stay tuned and keep coming with the ideas!
  10. B

    Hayward heater H100IDI

    I do not see anything in the parts list called a flame sensor. I will try to attach a diagram of the unit and parts. It is a Hayward H100IDI above grd pool heater.
  11. B

    Hayward heater H100IDI

    I have this hayward heater and it will not stay lit. It fires up for about 8 sec and then goes off, cycles again, fires up and goes off. The good thing is that it does at least light up. I have cleaned every piece on it down to the burners, blown gas pipe/valve out, jumpered every switch and...