Recent content by BassTrix

  1. B

    SWG Power Supply Behavior

    Update to my situation: Since my last post, I have disassembled the controller to inspect for any obvious issues. The only issue found was "winter mode" switch that was not fully actuating to the off position due to interference with the plastic housing. I opened up the hole so the switch...
  2. B

    New SWG needed

    I'm in a similar situation. My 21 year old Ecomatic has been acting up....I discovered the "winter mode" switch was not completely sliding over to the off position. I clearanced the opening for the switch and system no longer goes into the error state, but the controller still gets "stuck" in...
  3. B

    SWG Power Supply Behavior

    Yes, the test result is 4800ppm and 12ea 44lb bags of salt were added. The manual states a minimum of 3000ppm and a max of 6000ppm.
  4. B

    SWG Power Supply Behavior

    My pool has an Ecomatic ESC16 SWG. I'm sure it's original to the pool, which makes it about 20 years old. Last weekend I did a drain and refill and noticed the PS is behaving differently. It remains in standby mode for extended periods of time. Standby mode is normal during startup and...
  5. B

    Looking for tips to remove stuck Paramount popup cleaning heads.

    My pool has the large style Paramount pop ups. I have one that I need to repair/replace but it's stuck due to sand and grit. I have the removal tool and I know they turn clockwise for removal. I had the pool drained this spring and was lazy and didn't work to free all of them up...now I'm...
  6. B

    CYA Level Dropped Significantly Since Last Season!

    Here's a follow-up on my situation. On the 21st, I noticed a light dusting of olive green/brown forming on the floor of the pool so did a SLAM for mustard algae assuming I had 65ppm CYA. That was cleared up rather quickly since I caught it early on. The next day, my new bottle of CYA reagent...
  7. B

    CYA Level Dropped Significantly Since Last Season!

    Thanks for the response. I did not realize that CYA degrades by 3-5ppm/month. I have read on here that the only way to reduce CYA was by removing water, osmois treatment, or some new chemical treatments (that don't seem fully proven). Good to know there is degradation and that I need to check...
  8. B

    CYA Level Dropped Significantly Since Last Season!

    I have a dilemma to which I'd like the experts to provide feedback on. As temps rose this year, my SWG has had problems maintaining an FC level which has historically been easy to meet in prior seasons (when SWG is run for same duration). Eventually, I arrived at checking the CYA level as a...
  9. B

    Kool Deck Delamination vs Saltwater Pool?

    Hey folks! I am back on to solving this issue and began searching...my thread immediately popped up...I'm not sure why, but I never saw all these responses. So, to start with, I'd like to say thanks for the replies! Over the course of the year, the delamination has progressed and will soon...
  10. B

    Kool Deck Delamination vs Saltwater Pool?

    Bumping back to the top, hope someone has some input on the kool deck.
  11. B

    Kool Deck Delamination vs Saltwater Pool?

    It will be 3 years in July since moving into this house. There was about a 10ft wide swath of Kool Deck near the steps leading into the pool that was completely delaminated. Our realtor had former experience working for a pool builder and said that kool deck was more susceptible to failure...
  12. B

    To Drain & Fill or go Another Season

    Thanks guys, this is exactly the kind of info I need. Going to refill.
  13. B

    To Drain & Fill or go Another Season

    Currently, my CH is at 800. Last year at this time, CH was 500. The last time I did a D&RF was 2 years ago. Fill water CH ranges from 170-200. It appears that I'm picking up about 300ppm/yr. Today's numbers are: FC: 5.0 CC: 0 pH: 7.97 (dropped to 7.5 just after test) TA: 80 (should...
  14. B

    Question about calculating pump run time.

    Nesto, your pump should have a table with various curves for different pump RPM. As long as you can set the RPM, you should be able to dial in the flow you want.
  15. B

    The husband finally let me take over and I don't want to blow it!!

    When I enter your numbers into poolmath I get 121 oz of borax = about 7.5 lbs. This will raise your pH to 7.2 and bump up TA by almost 10. CSI should be -.22 which is very good.