Recent content by az1324

  1. A

    Pump Overheating & Trouble Starting

    Any comments on whether it should spin freely? My other motors do but they do not have start capacitor/centrifugal switch.
  2. A

    Jandy wireless OneTouch problem "Water temperature short"

    Sometimes the board can be damaged requiring repair or replacement.
  3. A

    How does a switchless 2 speed pump function?

    I thought it was recommended for most 2-speed pumps and also how the automation systems do it (enforce a delay before switching to low speed).
  4. A

    How does a switchless 2 speed pump function?

    Well since you can't start the pump in low speed you would need another timer to automate the high/low switching (T10604R). So if it is designed to run 24hrs cycle most of the time at low speed and part time at high speed this is the only way to do it with 1 timer. At that point you may want...
  5. A

    Builder forgot supply line for water features - Plan B?

    Do you really need the second pump? Why not put a valve actuator to switch between the standard return and the water features. Ramp up the speed on the pump when the features are on if you need to. - - - Updated - - - That is what he's saying but two pumps competing over 1 suction line...
  6. A

    Pump Overheating & Trouble Starting

    Voltage is fine and I'm running a different motor on the same supply right now with no issues.
  7. A

    I have a hose bib on pipe between pump discharge and filter. What is its purpose?

    Also for filling a dry pump before priming. Pool techs sometimes carry a short hose with two female ends to do this.
  8. A

    Pump Overheating & Trouble Starting

    So I pulled the motor apart again and can't see any obvious problems. When spinning the shaft, it will stop and shudder like some sort of magnetic brake has been applied. Is this normal?
  9. A

    Pump Overheating & Trouble Starting

    There was no mismatch of motor/impeller. I have now swapped filter pump and water feature pump so I can work on it without filtering downtime.
  10. A

    Pump Overheating & Trouble Starting

    Capacitor gives correct value on a meter. The hottest part of the case is directly above the coils. Capacitor housing is not hot compared to that.
  11. A

    Pump Overheating & Trouble Starting

    The motor has only a start capacitor ~300uF. It is a 2HP 240V motor. It stutters when it starts. Once it has been running for an hour the case measures around 80deg C. I just noticed these issues recently and it has been installed for several years. When I changed the bearings I made sure...
  12. A

    Pump Overheating & Trouble Starting

    I believe the motor is 10 years old. It is not original to the pump, but wet end is also approx 10 years old. It can run (hot) for several hours before shutting down. I don't have a clamp meter to read the current. The voltage is correct. The whole housing gets hot, I haven't checked the...
  13. A

    Pump Overheating & Trouble Starting

    My pump motor is running very hot and eventually reaches thermal shutdown. It also has trouble starting. I replaced the bearings and cleaned the contacts of the centrifugal switch. However this did not solve the problems. Should I change out the start capacitor? Could a bad start capacitor...
  14. A

    Plumbing Question: Solar Booster Pump

    Well it worked but I wasn't ever that impressed by it. Yeah I'm sure that's the way it is connected.
  15. A

    Plumbing Question: Solar Booster Pump

    Well I did mention in-floor cleaner in one of the posts above. It's a Caretaker system with 5 zones and 19 total heads. I would like to be able to run both at the same time since it is a good way to distribute heat. Ideally I would never have to switch the in-floor returns off even if I am...