Recent content by ausmoran

  1. A

    StaRite Heater Question (SR2000NA)

    I just want to pass along my most sincere thanks. I spent several hours working on the heater yesterday and replaced a few wires in the low voltage section (soldered in new ones, using heat-shrink to cover/insulate the repair), and then simply wrapped many other wires that had been gnawed by...
  2. A

    StaRite Heater Question (SR2000NA)

    You have been incredibly kind and helpful, Ted. Thanks ever so much. I hope to dig into it this weekend, so will let you know!
  3. A

    StaRite Heater Question (SR2000NA)

    Ted, Thank you ever so much! IT looks like they've done a substantial amount of damage to the wiring so I am not sure that electrical tape will suffice, though I will certainly give that a try. When I looked at the parts list, it didn't appear as though one can purchase the wiring harness...
  4. A

    StaRite Heater Question (SR2000NA)

    Well, just as you suggested, it appears that MICE spent a cozy Northeastern Winter living inside of the control panel for this pool heater. They have managed to gnaw thru a lot of the wires, so I will have to replace one of the harnesses (how difficult is it to replace the entire wiring...
  5. A

    StaRite Heater Question (SR2000NA)

    Okay, I hope to be able to pull the case off of the unit today! Thanks very much for such kind and willing help. I'll let you know what I come up with. Regards, Austin
  6. A

    StaRite Heater Question (SR2000NA)

    Thanks ever so much! This has been a very reliable pool heater....and not that old. I hate to think that the thing has died after only a few years! Cheers, Austin
  7. A

    StaRite Heater Question (SR2000NA)

    I have a five year old SR2000NA in-ground natural gas heater that has performed brilliantly for the past four years. Unfortunately, this year when I opened the pool it will not operate. The display shows code "E01" and the SERVICE HEATER incicator is illuminated. I have searched everywhere...