Same issue, but that one ran for a full year (operating 24/7 during pool season) before burning out. Another pump, one that came with the house, also did not work for some unknown reason (it was 10 years old and simply didn't start the first time we opened the pool.)That is an up rated motor. But what happened to that motor? Did it have the same issue.
Right but that usually means it is a 1 HP FULL RATED impeller. You have an UP RATED motor so it is a mismatch. You need a 3/4 HP full rated impeller instead.The part number of what's in my wet end matches up with what it says online is a 1 HP impeller.
Clogged lines under load a motor (not moving as much water), not overload so it would not burn up a motor. Also, are you sure that gauge isn't reading "in. Hg"?im suspecting something else is definitely wrong, like clogged/blocked pipes. There was barely any pressure being read on the suction side of the pump, I believe 2 mm Hg maximum on the gauge I installed. That seems a bit low for a skimmer line and a vacuum line.
Actually it's been FOUR now, but three of them have been attached to the current wet end. The Waterway SMF-110 pump had an EUSQ-1102 single speed motor that ran for a year until it started doing what the new two-speed 1072R motors are doing."... Two motors, both going bad, points at something wrong OTHER than the motor.
The original pump with the 1102 motor ran 24/7 during pool season, as we did not have a timer until AFTER that one broke down. To be honest, had that 1102 motor not broken down, I'd probably STILL be running it 24/7.How about the contacts in the time clocks and/or both "speeds" being energized at one time?
No, not that I've seen. There's only one junction point, and I ran brand new wiring from that to the timer box.How about a wonky breaker? Intermittent wiring (wire nuts and/or corrosion)?"
What does this mean? I just installed gauges on both sides of the pump, but I have no reference for what the readings are telling me. The impeller side reading is reading a bit lower than it did previously, going down closer to 15 whereas is had been 25.2" of mercury, that's not even 1psig vac???
It's been covered: http://www.troublefreepool.com/thre...seless-wet-end?p=905273&viewfull=1#post905273again, have you checked for reverse rotation, or both speeds energized simultaneously?