Aquatrol assistance

That is so weird that your highlight indicates a 1.47 version when my display says 1.17 and AL-7. Something very weird , which explains why I've never got good readings since I've bought this house. Do the aquarite and aquatrol boards look the same as well? Just wondering if they put in a replacement aquarite board at some point?? Anyways, I'll post diagnostics this evening
 
It does show Aquatrol HP made in September 2010.

It looks like the Hi salt happens at 5 amps for the T-5 cell.

You can jump the J4 to make it go up to 8 amps before giving a hi salt light.

1720574434238.png

1720574335998.png
 

Enjoying this content?

Support TFP with a donation.

Give Support
It does not have pins.

If the flow switch does not work, the system is not safe to use without having the cell mounted like in the diagram.

You have to figure out how to change the cell location or how to get the flow switch working.
 
I will try that tonight. Right now, it acts like its reading the flow. It starts out red with "no flow", then it picks up a flow and then it starts generating( for a few minutes anyway, until it reads high salt)

An RJ with no flow switch does that as well. An RJ cell will show "no flow" for a while (maybe 30 seconds) and then start generating. Even though it knows it does not have a flow switch, it still goes through that process.
 