Help - A diagnostic challenge(with no unifying answer?)
History of present illness
1 Jandy Stealth pump (3 years after replacement of dead single speed original motor with 2 speed Century 2–2.5 hp) [edit - actually 1.5->2.2 hp] shows diminished volume, begins to make noise , then quits pumping but runs.
2 I replace the diffuser broken into two pieces, and things work well with full restoration of flow for a week
3 Wife notices fountain not working but polaris 280 slowly moving on bottom. Pump is off and hot.
4 Pump allowed to cool down and is restarted with normal function and no noise but pump starts to run hot (171 deg max) though pump doesn’t turn off.
5 Smell of burnt plastic or insulation noticed from Jandy Aqualink RS box.
6 Filter pump does not go into low speed mode though PDA shows in low speed mode
7 Polaris cleaner booster pump is on but does not respond to control board although light above button goes on and off when pressed
8 ON opening Aqualink controller box - 3yr old 2 speed relay is melted.
Questions
Pump temp and increased Amperage (171 deg, 9 amps using old RS clamp ammeter)
Is there a unifying defect ( excluding the owner)? or are there two bad relays (filter pump and cleaner pump)?
How do I rewire in the short term so I can use my chlorinator and not burn up my cleaner pump?
My short term (tomorrow) plan - I need chlorinator.
Keep stuff turned off at breaker box until -
Check pump and diffuser in case there is pump obstruction. Take it apart again?
Figure out how to test cleaner pump relay.
Figure out how to take old 2 speed relay out of path and still get power to filter pump.
Put switch(?) on cleaner so it won’t run all the time.
Order new 2 speed relay switch
Try to figure out why filter pump runs hot
I apologize for the length. Thanks for any input
David - Dallas
History of present illness
1 Jandy Stealth pump (3 years after replacement of dead single speed original motor with 2 speed Century 2–2.5 hp) [edit - actually 1.5->2.2 hp] shows diminished volume, begins to make noise , then quits pumping but runs.
2 I replace the diffuser broken into two pieces, and things work well with full restoration of flow for a week
3 Wife notices fountain not working but polaris 280 slowly moving on bottom. Pump is off and hot.
4 Pump allowed to cool down and is restarted with normal function and no noise but pump starts to run hot (171 deg max) though pump doesn’t turn off.
5 Smell of burnt plastic or insulation noticed from Jandy Aqualink RS box.
6 Filter pump does not go into low speed mode though PDA shows in low speed mode
7 Polaris cleaner booster pump is on but does not respond to control board although light above button goes on and off when pressed
8 ON opening Aqualink controller box - 3yr old 2 speed relay is melted.
Questions
Pump temp and increased Amperage (171 deg, 9 amps using old RS clamp ammeter)
Is there a unifying defect ( excluding the owner)? or are there two bad relays (filter pump and cleaner pump)?
How do I rewire in the short term so I can use my chlorinator and not burn up my cleaner pump?
My short term (tomorrow) plan - I need chlorinator.
Keep stuff turned off at breaker box until -
Check pump and diffuser in case there is pump obstruction. Take it apart again?
Figure out how to test cleaner pump relay.
Figure out how to take old 2 speed relay out of path and still get power to filter pump.
Put switch(?) on cleaner so it won’t run all the time.
Order new 2 speed relay switch
Try to figure out why filter pump runs hot
I apologize for the length. Thanks for any input