We have a circupool RJ-45 that we installed in 2019. Things have been ok until this season. The system will run a few weeks and then the Lo Salt/Cell Maintenance lights come on and stop chlorine production. We clean the cell and then get a few more weeks.
Yesterday after a week of no swimming, we discovered the pool was slightly cloudy and no chlorine (I’ve been checking levels about once a week). The lights are on again, we do another cleaning. Then this morning, the water is even cloudier and 0 chlorine still. I cleaned the cell again and I shocked the pool and checked my chemicals.
The Taylor salt reading is 3500 while the RJ-45 is showing an average of 2300. I added 4 bags of salt just to be safe. I then watched as I would turn the system off and about 3 min later lo salt would flash for a few seconds and then the cell maintenance light goes on and the unit stops production.
Do I need to wait longer for the salt to circulate? But also why would there be such a discrepancy in the readings? And if it’s just low salt, why is the cell maintenance light flashing? Would it be possible that we need to replace this after 3.5 seasons? We run the unit on 40% 24hr (no automation
) for roughly 3 months a year.
Yesterday after a week of no swimming, we discovered the pool was slightly cloudy and no chlorine (I’ve been checking levels about once a week). The lights are on again, we do another cleaning. Then this morning, the water is even cloudier and 0 chlorine still. I cleaned the cell again and I shocked the pool and checked my chemicals.
The Taylor salt reading is 3500 while the RJ-45 is showing an average of 2300. I added 4 bags of salt just to be safe. I then watched as I would turn the system off and about 3 min later lo salt would flash for a few seconds and then the cell maintenance light goes on and the unit stops production.
Do I need to wait longer for the salt to circulate? But also why would there be such a discrepancy in the readings? And if it’s just low salt, why is the cell maintenance light flashing? Would it be possible that we need to replace this after 3.5 seasons? We run the unit on 40% 24hr (no automation