Whisperflo vst and easytouch

Npotter

In The Industry
Apr 21, 2023
11
Norcal
I just acquired a pool on my route, the customer had a whisperflo vst installed along with an easy touch, is the rs485 cable supposed to be hooked up to the com port with the green and yellow wires, it's currently connected with all wires to the spa side remote..?
 
N,

VS pumps should get constant AC power, so yes, the line side of the pump filter relay or directly to a circuit breaker.

It should NOT be in external mode which is for relay inputs.

If this is the only pump then it should be set to address #1

If it is not the main pump, then you need to set the address to #2 or at least not number 1.

When the automation is in control of the pump, its screen will flash between Auto and RPM/speed

Thanks,