Thanks... I took a look at your documents. Looks pretty good IMO. Just a couple of questions/comments.
1. With an IC-60, do you really need the Rainbow In-line 320 Auto-Chlor?
2. If it were me, instead of having two each, 2-way Jandy Valves for each skimmer line, I would have both skimmer lines coming into a 3-way valve instead.
3. You have 10 breaker spaces in the load center. You are showing a Siemens First Surge FS100 but don't show it taking up any breaker positions. That surge protector requires a double-pole breaker (2 positions). Looks like you have no room for it. Best you can do is install one on your house breaker panel I guess.
4. Why a creepy krauly instead of as Maytronics Robot? You can even connect some robots up to automation (relay controlled power receptacle). A Maytronics is much more efficient. I have a suction-side cleaner ONLY because it's a tank and won't die (and don't think I haven't tried to kill it).

. As soon as it needs a rebuild, I'm calling Marina Pool and Spa. I already have the receptacle wired up to the power relay in the IntelliCenter OCP.
5. On a side note, I agree with
@Jimrahbe and
@Turbo1Ton with having two each 2-way valves for the water features instead of a single 3-way. Makes a lot more sense. You can automate each one with an actuator if you like. Off (home position), and On (preset 2nd position) for each valve, but a single 3-way will not give you the control that you desire I believe.
r.