OK -- good info. However, those are not spa jet nozzles. They are return nozzles for the regular pool.
Thought I would report back on this as it is finally solved. After over a year of troubleshooting and 4 pool companies telling me to just add a blower, one fellow came out and listened to the symptoms and said a check valve was broken. Sure enough the check valve right after the heater was broken and the flapper inside was floating freely and sealing up the outlet to the valve. A new valve and it’s all fixed! I very much appreciate all the help!Look at the site I linked. There is a pic of a jet body.