So I posted earlier about having a green pool. I have followed the advice in doing a SLAM and tearing every day with the TF100 test kit.
For a brief overview, my results are
FC 18
CC 2.5-3
TC 20-21
CYA 40
TA 160
CH 300
PH 7.5
I have achieved an overnight loss of less than 1 and the CC is less than 5. The water has gone from green to cloudy blue. I can only see about 1 to 2 feet in depth so the water is pretty cloudy. I was wondering if I need to continue to SLAM until the water is clear or if I should let the FC die down to maintenance levels? Basically will this be filtered out in time without keeping shock levels? The water looks clean but not sure how to proceed to fully clear it up. Thanks.
For a brief overview, my results are
FC 18
CC 2.5-3
TC 20-21
CYA 40
TA 160
CH 300
PH 7.5
I have achieved an overnight loss of less than 1 and the CC is less than 5. The water has gone from green to cloudy blue. I can only see about 1 to 2 feet in depth so the water is pretty cloudy. I was wondering if I need to continue to SLAM until the water is clear or if I should let the FC die down to maintenance levels? Basically will this be filtered out in time without keeping shock levels? The water looks clean but not sure how to proceed to fully clear it up. Thanks.
Last edited: