hayward

  1. B

    Omnilogic ghost alarms!

    Yesterday we experienced the typical power surge. It was very quick. About 15 min later I received 3 alarms on my Omnilogic Apple App. I immediately went to the console and rebooted it to see if the alarms would disappear. They went away on the console but stayed as alarms on the app!?! I...
  2. W

    Hayward T 925 salt cell voltage, no amperage connected to omnilogic.

    I opened the pool the other day and the salt cell was working fine. 3 days ago, I replaced the Ecostar pump with the thp vs pump and reconfigured the omnilogic. Salt cell stopped working, so I went in and saw that I must have selected the previous cell and I changed it to the correct cell but...
  3. PoolBrews

    Hayward ColorLogic Light Longevity

    Curious what others have seen with regards to longevity on the Hayward ColorLogic lights. I have a Hayward LPCUS11100, and my pool was completed in October of 2019 - so it's only a little over 3 years old... and just outside of warranty. The other day we turned it on, it ran for about 5...
  4. W

    2.7 thp vs low voltage connection to omnilogic

    I swapped out an Ecostar for a vs and having a hard time trying to find specific schematics for connection to omnilogic. The manual shows a very different wiring setup than what I have. Before, I had a two wire connection to the eco star but now there are two insulated conductors and a shield...
  5. C

    Hayward VSP pump is pulsating

    I have new vinyl liner pool that was completed late last summer. I have one pump that just controls my water features (3 sheer decent and 2 bubblers). It’s a Hayward VSP 2.7HP. No filter attached to the feature pump. When I turn the pump on high, I hear a pulsating noise seemingly from the pump...
  6. B

    Hayward Heater Needs New Heat Exchanger After 1.5 Years??

    Hi Everyone, Looking for a second opinion on an issue we are having with our spa heater. We built our house a couple of years ago and have a large pool and large spa. The spa is around 2500 gallons and is used year round in a cold weather environment in northern Ohio (my wife is nuts). This...
  7. P

    Aqua Logic Glx-Pcb-Main RTC Issue

    Hi, I hope someone out there can help me with the RTC circuit. I have purchased the super capacitor, RTC chip and oscillator. Upon initial inspection I noticed a SMD capacitor is missing C-14, does anyone know the value of this component and the +/- position to mount a replacement as well as the...
  8. G

    Replacing a Hayward On Command automation system

    Hi, I currently have a Hayward On Command system connected to a Hayward VSP, and Hayward pool,and 2 lights. Looking to upgrade to a Hayward OMNI PL system for the web app convenience. Our remote died in the fall and I can’t justify paying $500 more for this system. Does anybody know if the...
  9. S

    Hayward booster pump stopped working

    Could someone help troubleshoot this problem? My Polaris sweeper stopped working the other day. The booster pump Hayward 6060 didn't start, even if I tried to start it on the main panel of the controller (mine is Hayward OmniLogic.). My booster pump is 5 years old and I jumped to a conclusion...
  10. R

    Hayward Omni Hub, Control Pad replacement

    I have Hayward VS Omni pumps and Omni Hub automation. The control pad is damaged. I have a troubleshooting guide with the part number listed as HLHCONTOL but I am unable to locate a replacement. I can find a replacement case and LCD screen but I am unable to find the board. Does anyone know...
  11. A

    Hayward/Omnilogic not controlling the heater

    We have a Hayward system using an Omnilogic control panel. It used to seamlessly all work together, where I could set schedules and the pump and heater would come on when desired and switch between the spa and the pool without issue. Recently our (now former) pool maintenance person shut it all...
  12. R

    Harward SP2300VSP MAXFLO repair bearing possible?

    I have a Harward SP2300VSP MAXFLO VS pump that I purchased a few years back. It's making noise during regular operation and after checking the impeller etc. have come to the conclusion that the bearings are the cause. Searching online there isn't much documentation on replacing these bearings...
  13. A

    Hayward Max-flo VS SP2300ZLV NO POWER

    we just got done with Hurricane Ian and prior, I turned off the breaker to the pool just in case we got water, it wouldnt burn out and short the pump. Home now, turned on the breaker and nothing. No display. I checked that I have power to the motor and I have power. Motor is doing nothing...
  14. I

    ProLogic + AQL2-POD = Basestation Not Responding

    Hi, I have my AQL2-BASE-RF connected to my ProLogic, and my AQL2-POD reads full bars but reads base station is not responding. I also do not have the option to "teach wireless" for the remote on my ProLogic settings menu. Any ideas on steps to try and how to get my remote connected would be...
  15. D

    Can I replace a Hayward GLX-PL-LOC-P-4 with the cheaper GLX-LOCAL-P-4

    The cost of a new PL display board is over $500 and the cheaper one is $225. I lost my job recently and this is put me in a tough bind. The display just displays "Communication Error". I tried to see if it was the board or transformer but both seem to be working. After I tried to diagnose the...
  16. HikeAbout

    Suction-Side Air Leak? A Plea For Help!

    Hello TFP! My husband and I just bought a new house with a 20-year-old in-ground concrete pool. It has two skimmers, two jets, and no main drain. The pump and filter are both below grade (in our basement). The pump is a Hayward Super Pump and it connects to a sand filter. We're pool beginners...
  17. prinzlmeisl

    New Hayward Superpump is extremely noisy

    I like to have a spare pump around. The price of this pump has tripled in recent years, but I decided to get a new one anyway when my current pump started to leak, so I could repair it at my own pace and keep it as a backup. Unfortunately, this did not work as planned. The new pump is...
  18. J

    Talk me off the edge! (Automation, etc.)

    OK. I am pretty frustrated with my equipment (pump-swg), and I am considering starting over. I want my automation to work more smoothly, and I'd like to gain some reliability. What I have: Control: iAqualink 2.0 with the V2 board. Main Pump: A centry V-green pump. I have the V-Green...
  19. W

    Rookie Pool Owner in NJ

    Hey y'all - second summer with my pool, was finally getting into the swing of things, had to have a pretty decent amount of cement work done a couple of months ago and a lot of the dust got into the pool... In retrospect I should have put the filter on waste but had it just set to filter...
  20. B

    Hayward Skimmer questions

    Hi! I am a new AGP owner. I need to install a skimmer as I have trees nearby. I purchased the Hayward wide mouth skimmer (Hayward SP1091WM Dyna-Skim Above-Ground Pool) based on several youtube videos I watched, but now that it's here, I'm considering installing the standard instead. Because...
  21. S

    HELP! Hayward heater and Omnilogic controllers - app is not switching heater back and forth

    Hi there, I am new to the forms but was searching and found a few related posts - so thought I would make one and hopefully get some help. We built our 18x36 pool 2 years ago. We are using hayward and omnilogic products. 6 months after our pool was operational (it is salt water), the heat...
  22. F

    Hayward Firmware Upgrade Disabled Features such as Heater, Lights, Filter etc

    We received an email telling us to update our Omnilogic firmware. After many attempts, to download the upgrade via the USB and Internet we were able to download all of components except to MPP. After calling Hayward their first question was to get hte serial number and notify us it was outside...
  23. E

    Hayward Aqua Rite system won’t let me change the cell type. Help!!

    I just got a new salt cell and when I went to use it. the system started generating then the check salt and inspect cell lights come on and it won’t let me change the cell type it just stops at the Circuit board revision screen. I’m thinking it being the wrong cell is the problem why it’s not...
  24. C

    Hayward How to Delete MSP from Dashboard to enable Alexa Connectivity

    Hey all. This is regarding the Hayward OmniHub System as it connects to Alexa. I had an old OmniHub that became defective within the warranty period. So a Hayward rep came and replaced the part with a new MSP. However, the old MSP site still shows up in my dashboard as "inactive" alongside the...
  25. Joe Garcia

    Jacuzzi JVS 185S Above Ground Pool Pump...Simply Awesome from A-Z!

    My 10 year old single speed pool pump recently started to go south and I knew it was time for a change to a variable speed pump to save some money on my energy bill. Before my pump totally died I thought I should do some research on the main brands like Hayward and Pentair. I went to my local...
  26. K

    OmniLogic app won’t change pool temp

    Hi, I’m having an issue with my Hayward heater not being controlled by the OmniLogic app. I can turn on pump, lights, even turn on and off heater via app but if I change temp it doesn’t change. I have to go out to the actually heater and move it up or down. A few weeks ago we opened our pool...
  27. I

    no heat

    inground, hayward prologic with salt system and hayward gas heater. water, gas and elec are fine. not calling for heat. any ideas?
  28. P

    Hayward GLX-PCB-MAIN - Low Salt - Low Current

    I have a GLX-PCB-MAIN which is now not putting out the full 6-7 Amp needed to drive the T-15 Cell. I have verified the Cell - it works correctly. The Board will start with 25V range - reporting 3400 PPM then quickly drop to 1900 PPM while reporting 25.5V at 4 Amp. It did start with 6 Amp...
  29. M

    Hayward Automation Question - How to interlock and schedule my heater/salt chlorinator

    I have a Hayward OmniLogic with a Hayward VS Pump and salt chlorinator with a sense and dispense. The system is in a configuration with a shared heater/filter for a pool/spa with a spillover. I have found through my own trial and error that heating the pool while in spillover is REALLY...
  30. M

    Hayward Jiffy Niche