Search results

  1. C

    Bonding

    My 2 cents from the states. What you have top remember is that all codes are the bare minimum. Going above the minimum in a swimming pool surrounding is something you will have to say is worth it. Below are my opinions and I don't carry licence to do work in your area. So truly my words mean...
  2. C

    Help with pool controller location

    I have to agree with Maddie and Jim. My opinion is the location installed is the best from the pictures you have shared. Circle 1 behind equipment. Definitely can't go there. Circle 2 on the left: Facts 1- It appears in the picture you meet the working clearance of the equipment. 2- I...
  3. C

    Raceway vs Residential Branch Circuit

    First issue I read is Romex in conduit. Romex isn't rated for wet locations. As far as 12" or 18" - Will your circuit be 20 amp or less and have GFCI protection?
  4. C

    Help with pool controller location

    Without a picture of where the electrician installed it and where you wanted it... I'm of no help. But the code he is referring to is.... Imagine a box in front of your controller... width of controller, height(all the way to the ground) and 3' in front of your controller. Nothing can be inside...
  5. C

    Filled in pool

    DO you have a copy of your plot survey plan(If not the city should)? I would think in order for the power company lines to be in your back yard they would have at one point asked and issued an easement. Knowing where the easements on your property could get you started in the right direction.
  6. C

    DIY L Shape - Getting ready for action

    Any updated pictures?
  7. C

    DIY L Shape - Getting ready for action

    so maybe $1000 in material. Rental of Mixer $200 or less for the day 1500 for labor - If it was me I would pay. Unless you have a few friends or family of free labor. I would make it clear that there are no extras and hand over the finshed pool floor plans to be implemented. Just my opinion
  8. C

    DIY L Shape - Getting ready for action

    Does the Quote of 2500-3000 include sand and Portland?
  9. C

    Vinyl 18x36 on the way. Here is the gameplan!

    Looking at your pictures you don't need a portland base with that hard red clay! Just kidding Keep up the good work your half way there! and a couple steps away from the weather being your worst enemy.
  10. C

    DIY L Shape - Getting ready for action

    If the transformer has only one concentric knock out in the 12volt side of the barrier. Then yes the easiest way is like you said. Bring both lights to a LJBUY00PP1 and single conduit to the LTBUY11300. The junction box can be right beside the LTBUY11300. Just make sure you install...
  11. C

    wiring a 1 1/2 hp 15 amp pump for an above ground pool.

    Wire Size I suggest #10 wire at the minimum. < 3% voltage drop at 14 amp draw from the motor. #12 would give you a VD of around 5% There is variables: True RMS voltage, Actual amp draw from the motor nameplate and true length Just my two cents. If you pulled #12 would it work. Short...
  12. C

    wiring a 1 1/2 hp 15 amp pump for an above ground pool.

    I agree with Dan, 1" or at the bare minimum 3/4. I don't know your situation, you may need a second circuit for the convenience outlet >6 not more than 20. Don't forget your bonding inspection will take place with this permit. Can you confirm the nema configuration of the plug shipping on...
  13. C

    Attaching bonding wire to pool ladder, need suggestions...

    Out of curiosity, Why are you replacing the pool ladder? Are you currently feeling a shock entering and exiting the pool? Is this how you know it isn't bonded? Are you replacing the anchors cups as well? or are you saying there is no wire wire attaching directly to the ladder other...
  14. C

    New IG vinyl pool build in North AL

    Looking good!
  15. C

    New IG vinyl pool build in North AL

    Any progress?
  16. C

    New IG vinyl pool build in North AL

    Kyle- Saving 8-10K should put a smile on your face! I know it would for me! When your done I would love to see your actual costs for future reference. Do you have big rain coming in soon?
  17. C

    Wet light niche

    Internal ground goes to lug inside light niche to ground bar in wet niche J-Box. There should be an external lug on both light niche and J-Box that you take a separate wire to the grid. Hope this helps, Chris
  18. C

    Wet light niche

    Is there a place locally that would sell the potting compound? We buy our potting compound at the electrical supply house. Most electrical inspectors in the our area want to see the ground in the niche and the compound installed.
  19. C

    New IG vinyl pool build in North AL

    Kyle- Google curtain drain(type of french drain for surface water) and take a look and see if that would work. You might okay with just gutters and diverting the water away from the area. It's hard to tell from the pictures and what future concrete decking you are installing. Dry...
  20. C

    New IG vinyl pool build in North AL

    Just a thought.... But you might want to think about installing a french drain to divert the rain water from the roof and slope of the pool. All that water on your foundation won't be good. I'm by no means an expert though! If you don't and later you discover there is a problem. Install some...
  21. C

    New IG vinyl pool build in North AL

    I love watching DIY threads! I'll be doing a DIY next April. If you don't mind me asking where did you purchase the Pool Kit from?
  22. C

    New Construction - please review contract specs for issues..

    Re: New Construction - please review contract specs for issu As long as everyone understands the NEC is the minimum standards. Some municipalities lag in years before adopting the new code books. When you DIY's pull your permit, check permitting which book they are using.
  23. C

    New Construction - please review contract specs for issues..

    Re: New Construction - please review contract specs for issu Out of curiosity what does the 2011 NEC state?
  24. C

    pool construction safety procedures - any?

    I agree with you! If not for the safety of the workers.....Then for the home owners family!! I believe if your check the OSHA book(1926) you will find out that they should have caps or I've seen them install wooden box/2x4 troughs on the top). This is my opinion though check the standards out...
  25. C

    New DIY build in Oklahoma

    Are the threads on the inside of the niche? If so, They are for testing the conduit system for leaks before back filling and installing the fixture.
  26. C

    New DIY build in Oklahoma

    I bet that is a relief to put the liner in and know that it fits....LOL Your hard work is steadily showing rewards! In your scenario, How high did you place the top of the pool walls above finish grade/old grade? Thanks for walking us through your build with pictures!!!
  27. C

    New DIY build in Oklahoma

    At least you're over the hump!! If it rains you shouldn't be effected to bad! Can you take a guess on how many man hours did you have on the vermiculite floor? Thanks for the pictures
  28. C

    New DIY build in Oklahoma

    Great work so far! Keep the pictures coming! How many bags of Pool Krete have you used so far?
  29. C

    DIY IG POOL - part 7 - electrical

    Re: DIY IG POOL - part 8 - electrical Also, Don't forget to bond or run the wire that connects all metal componets around the pool to the spa/pool motor and heater if applicable. This ensures everything to be at the same potetial. Chris
  30. C

    DIY IG LINER POOLS - part 6- leveling and pouring the collar

    Re: DIY IG LINER POOLS - part6- leveling and pouring the collar Ted, This great information and Thank you for taking the time! I do have one question, Typically what mix do you use on the collar? ie 3000 psi 4" slump Chris