Hot Spring Freshwater IQ 2024

The system notifications haven’t come on in several days .
The chlorine says still on low side but doing drop test shows 4-5 on chlorine levels.Have salt output on 3,system updates hourly and has a 24 hr cycle once a notification has occurred.
The sensor indicator at the very top of range,salt cell level shows middle of range and it’s only been in the hot tub for several weeks.
Will continue with updates to keep you all informed.
How’s the actual PH reading relative to the sensor reading? If the PH sensor is reading off from actual this would explain a drop test of 4-5 but the panel indicating a lower chlorine reading. Might be wise to log both actual PH reading and FC drop test compared to panel/sensor readings to see which parameter is at the root cause of the shift.
 
How’s the actual PH reading relative to the sensor reading? If the PH sensor is reading off from actual this would explain a drop test of 4-5 but the panel indicating a lower chlorine reading. Might be wise to log both actual PH reading and FC drop test compared to panel/sensor readings to see which parameter is at the root cause of the shift.
I have been logging them for years on any showroom hot tubs,we have a software program that I use for all testing I have performed also manually logged in a file for backup for any issues that happen.
That way any attempts at warranty disputes from manufacturers have been documented and done weekly,or bi weekly as per ownerships mandatory requirement for the job position.
We sold our first one Saturday and are delivering it next week so we will have our first customer adventure with a new system.
 
Last edited:
I have been logging them for years on any showroom hot tubs,we have a software program that I use for all testing I have performed also manually logged in a file for backup for any issues that happen.
That way any attempts at warranty disputes from manufacturers have been documented and done weekly,or bi weekly as per ownerships mandatory requirement for the job position.
We sold our first one Saturday and are delivering it next week so we will have our first customer adventure with a new system.
All going well on sensors/salt readings have salt output at 4 has maintained a 3-4 ppm on Chlorine and pH of 7.4-7.5 and TA of 85-90 CH 45
So far after getting original high chlorine level down the sensors have been responding accordingly.
 

Attachments

  • IMG_3751.jpeg
    IMG_3751.jpeg
    664.1 KB · Views: 3
  • IMG_3752.jpeg
    IMG_3752.jpeg
    391.4 KB · Views: 3
Last edited:
All going well on sensors/salt readings have salt output at 4 has maintained a 3-4 ppm on Chlorine and pH of 7.4-7.5 and TA of 85-90 CH 45
So far after getting original high chlorine level down the sensors have been responding accordingly.
My final test before draining spa APRIL 1ST
4.0 FC/4.0 TC
7.5 pH
85 TA
45 CH
SALT LEVEL 1800
PHOSPHATES 0
 