Difference between revisions of "Jandy TruClear SWG" - Further Reading

Line 2: Line 2:
  
 
The Jandy TruClear is an entry level SWG that Pentair specifies as being for pools up to 35,000 gallons. TFP recommends a SWG be 2X the pool volume and the TruClear be best in pools 17,500 gallons or less.
 
The Jandy TruClear is an entry level SWG that Pentair specifies as being for pools up to 35,000 gallons. TFP recommends a SWG be 2X the pool volume and the TruClear be best in pools 17,500 gallons or less.
 
[[File:Jandy TruClear Control Box.jpg|400px|thumb]]
 
  
 
The TruClear cell will generate 0.93 lbs (420 gm) per day if run for 24 hours.
 
The TruClear cell will generate 0.93 lbs (420 gm) per day if run for 24 hours.
Line 11: Line 9:
 
The TruClear will operate at flow rates of 20 GPM and above.
 
The TruClear will operate at flow rates of 20 GPM and above.
  
[[File:Jandy TruClear Cell.jpg|400px|thumb]]
+
==Power==
  
==Power==
+
[[File:Jandy TruClear Control Box.jpg|400px|thumb]]
  
 
The power pack must be installed at least 2 feet (0.6 m) vertically off the ground. Ensure the power pack is
 
The power pack must be installed at least 2 feet (0.6 m) vertically off the ground. Ensure the power pack is
Line 27: Line 25:
 
chlorinator only operates when the pool pump is operating. The flow sensor feature of the Jandy TruClear is intended
 
chlorinator only operates when the pool pump is operating. The flow sensor feature of the Jandy TruClear is intended
 
to be used as a backup only and should not be used as the sole source of flow detection.''
 
to be used as a backup only and should not be used as the sole source of flow detection.''
 +
 +
==TruClear Cell==
 +
 +
[[File:Jandy TruClear Cell.jpg|400px|thumb]]
  
 
The cell must be installed horizontally with the cord facing upwards to avoid buildup of flammable gases which
 
The cell must be installed horizontally with the cord facing upwards to avoid buildup of flammable gases which
Line 32: Line 34:
  
 
The cell must be installed as the last piece of equipment in the circulation plumbing system just before the pool.
 
The cell must be installed as the last piece of equipment in the circulation plumbing system just before the pool.
 +
 +
==TruClear Replacement Parts==
 +
 +
There are few replacement parts for the TruClear system.
 +
 +
For the cell:
 +
*TruClear Cell, Replacement (no Housing) - R0693900
 +
*TruClear Housing, Replacement (no Cell) - R0694000
 +
*TruClear O-Ring, Replacement - R0694100
 +
*O-Ring Tail Piece - R0449200
 +
 +
For the Power Pack:
 +
*TruClear11P Power Pack Cover Replacement - R0663800
 +
*TruClear PCB, Replacement Assembly - R0802300
 +
*TruClear Cover Screw Set - R0609400
 +
*TruClear Transformer Assembly - R0802400

Revision as of 21:12, 4 June 2022

Jandy TruClear SWG

The Jandy TruClear is an entry level SWG that Pentair specifies as being for pools up to 35,000 gallons. TFP recommends a SWG be 2X the pool volume and the TruClear be best in pools 17,500 gallons or less.

The TruClear cell will generate 0.93 lbs (420 gm) per day if run for 24 hours.

Power can be 120 volts or 240 volts 50/60 Hz using 2 to 4 amps. Output to the cell is 25 volts DC maximum.

The TruClear will operate at flow rates of 20 GPM and above.

Power

Jandy TruClear Control Box.jpg

The power pack must be installed at least 2 feet (0.6 m) vertically off the ground. Ensure the power pack is protected from direct water exposure from sprinklers, water runoff from rooftops and drainage.

In the US, the power pack must be installed at least 1.5 m (5 ft.) from the inside wall of your swimming pool or spa; in Canada, the power pack must be installed at least 3 m (10 ft.) from the inside wall of your swimming pool or spa.

The Jandy TruClear Installation Manual says:

The power pack must be interlocked/interconnected with the pool pump motor power source to ensure that the chlorinator only operates when the pool pump is operating. The flow sensor feature of the Jandy TruClear is intended to be used as a backup only and should not be used as the sole source of flow detection.

TruClear Cell

Jandy TruClear Cell.jpg

The cell must be installed horizontally with the cord facing upwards to avoid buildup of flammable gases which can result in FIRE OR EXPLOSION.

The cell must be installed as the last piece of equipment in the circulation plumbing system just before the pool.

TruClear Replacement Parts

There are few replacement parts for the TruClear system.

For the cell:

  • TruClear Cell, Replacement (no Housing) - R0693900
  • TruClear Housing, Replacement (no Cell) - R0694000
  • TruClear O-Ring, Replacement - R0694100
  • O-Ring Tail Piece - R0449200

For the Power Pack:

  • TruClear11P Power Pack Cover Replacement - R0663800
  • TruClear PCB, Replacement Assembly - R0802300
  • TruClear Cover Screw Set - R0609400
  • TruClear Transformer Assembly - R0802400