==Model Configuration==
 
==Model Configuration==
Both cells use the same Power Center box. However there is a jumper on the Power Interface Board that is connected fir the 1400 cell and cut for the 700 cell.  The Power Center comes configured for the 1400 cell and the jumper must be cut if using the 700 cell.
+
Both cells use the same Power Center box. However there is a jumper on the Power Interface Board that is connected for the 1400 cell and cut for the 700 cell.  The Power Center comes configured for the 1400 cell and the jumper must be cut if using the 700 cell.
  
 
If you are switching from the 700 cell to the 1400 cell the jumper needs to be reconnected.  
 
If you are switching from the 700 cell to the 1400 cell the jumper needs to be reconnected.  
  
Page 17 in the [https://www.jandy.com/-/media/zodiac/global/downloads/h/h0325600.pdf Jandy Power Center Installation Manual] shows the location of the jumper.  
+
Page 17 in the [https://www.jandy.com/-/media/zodiac/global/downloads/h/h0325600.pdf Jandy Power Center Installation Manual] shows the location of the jumper.
  
 
==AquaPure Resets to 35% Everytime it is Powered On==
 
==AquaPure Resets to 35% Everytime it is Powered On==

Revision as of 16:11, 16 February 2020

This article is currently incomplete. While this article is off to a good start, it still has room for major improvement. Until the article reaches its full potential, it will be hidden from search results.

Jandy AquaPure SWG

The Jandy AquaPure system consists of a Power Center and either a PURE700 cell or a PURE1400 cell. The AquaPure salt-water chlorine sanitizing systems uses salt water to deliver water sanitation by generating chlorine.

AquaPure cells connect with PureLink power center and AquaLink automation controllers.

Model Configuration

Both cells use the same Power Center box. However there is a jumper on the Power Interface Board that is connected for the 1400 cell and cut for the 700 cell. The Power Center comes configured for the 1400 cell and the jumper must be cut if using the 700 cell.

If you are switching from the 700 cell to the 1400 cell the jumper needs to be reconnected.

Page 17 in the Jandy Power Center Installation Manual shows the location of the jumper.

AquaPure Resets to 35% Everytime it is Powered On

A member had the problem of his Aquapure resetting to 35% every time it was powered on by the timer.[1] After discussions with a Jandy representative it was determined the problem was a bad board.

Power Center Transformer

Older Power Centers use a rectangle transformer P/N T1005 that is no longer available. Currently, Jandy has part R0481400 which is the round transformer.

A member found that the new part fit perfectly with the same mounting holes. Even the High Voltage side wires were color coded identically. The only difference is the new part has a ground wire that was attached to the common ground.[2]