gas

  1. K

    Gas smell from Jandy JXI exhaust

    Hello all! A little backstory; earlier in the year I had an electrical situation that ended up frying multiple parts on my Jandy XJI heater. I replaced the power distribution board, power transformer, Fenwal ignition control, and the blower motor. The heater worked like a champ all season and...
  2. F

    Need a new pool heater

    Hi all - my current heater (400K natural gas BTU Jacuzzi, 2013), seems to be done (changed a part 2x and should've put the repair costs towards a new one). My pool is roughly 30,000 gallons in-ground with a hot tub. I'm located in near SF in the East Bay - our area stays a few degrees cooler...
  3. C

    Gas Line Requirements

    Hey Everyone, I bought my house a couple summers ago and the previous owners left a brand new Raypak 266A pool heater in the pool shed. They never hooked it up to gas or electric but did have the pool plumbing connected (currently in bypass). I'm hoping to get it running this year but I think...
  4. OmniPools

    Minimax Heater NT; NOT IGNITING

    Hey yall! So I've come across an issue with a clients minimax NT. This heater will not ignite for no one. Currently I'm receiving 120v in and out of the hot surface ignitor, I can see it turning RED. The gas valve is receiving 24v at the blue and white wires. Incoming Gas pressure is 8" wc...
  5. J

    Natural Gas Pool heater experiencing delayed ignition - Troubleshooting

    Hi Folks, I'm hoping someone can point me in the right direction here. I have a relatively new Pentair MasterTemp 400 Natural Gas Heater. The heater works well when running but I'm having a delayed ignition issue where ,sometimes, when it clicks to turn on it will delay and then start about 30...
  6. A

    Hayward H400 Problems

    Hello, Ive read every post on this site and more trying to get my heater working and hopefully someone has the answer here.... so here is the events 1. heater worked flawlessly for years 2. heater stops working , continually blows f2 fuse on power board once blower motor fires up 3. replace...