    Lost communication only on first scheduled speed

    Thanks to you guys again!!!! Woke up this morning with the sound of water from spillway, scheduled program started working after 3weeks of waiting for pro local service guys to find out what’s wrong...
  2. H

    Lost communication only on first scheduled speed

    Thanks again for all the info, here is what I changed to, let’s hope it works tomorrow, :) Pool 5:00am to 10:00pm Cleaner 5:10am to 8:00am High speed 8:10am to 11:00am pool 1200RPM Cleaner 2600RPM High Speed 2200 RPM
  3. H

    Lost communication only on first scheduled speed

    Just a floater tablet holders
  4. H

    Lost communication only on first scheduled speed

    Yes it does turn off for couple minutes to not overlap and starts again...that’s what I’ve been told and read. All these and pool is new to me and just learning about it. In Oregon we didn’t need pool and just moved to CA and have a pool here !!! Lol I will try to set the schedule that way...
  5. H

    Lost communication only on first scheduled speed

    I did change all to rpm since our last conversation, figured out with combination of what I have set it will turn the water in the pool (to be exact 28k gallon) at least once during the day. High speed is mostly for cleaning the debris from surface (skimmer) also moves the water from...
  6. H

    Lost communication only on first scheduled speed

    5:00 am vacuuming until 8:00am(2600rpm), 8:10am to 10:55am skimmer (2200rpm), 11:00 am to 10:00pm just on low speed 1500rpm(1500rpm)
  7. H

    Lost communication only on first scheduled speed

    Thanks again Jim for all the help, 11:00 am setup was working before, now I have to wait until tomorrow morning to see the other two will come on or not. Also I was wondering myself how do they run business, lol Specially 2nd person that was Pentair certified too and recommended by them...
  8. H

    Lost communication only on first scheduled speed

    I wish I knew about Dolphin I would of gone that route, instead of spending on Intellivalve and the suction vac. Lol maybe next year...
  9. H

    Lost communication only on first scheduled speed

    Looks like with switching pump wires from load to line did take care of all! cleaner and high speed settings working properly with the speeds they are set. And yes intellivalve changes from skimmer to vac when I turn it on, and it’s set for 3 hours vacuuming. So hopefully tomorrow morning...
  10. H

    Lost communication only on first scheduled speed

    Thank you Jim for all the help and quick responses, we just finish redoing the pool plumbing and replastering, now the cleaner is suction side and I was complaining to installer because it was running with skimmer all day long, so I requested intellivalve to separate the skimmer and vacuum for...
  11. H

    Lost communication only on first scheduled speed

    Also previously cleaner was setup on 3 hours egg timer, 2nd person changed it and assigned to a valve and still not working, I can turn it on manually but works with pump speed not with what’s assigned to. What is the right setup/function for high speed and cleaner.
  12. H

    Lost communication only on first scheduled speed

    Jim, going in service mode did turn off the pump completely and nothing on pumps display
  13. H

    Lost communication only on first scheduled speed

    Hi, hopefully someone can help and tell me what’s going on here. We have installed easytouch pl8, screenlogic and Intelliflo VSF pump, scheduled 3 speed as follow: 5-8am cleaner with 2600 rpm, 8:10-10:55 high speed 2200rpm, 11:00 - 10:00 pm pool on low rpm, in the morning I’ll wake up and see...