    Raypak heater problem

    Storms last night (and dinner out) prevented me from trouble shooting but tonight looks good so I will try all the suggestions. I suspect the generator may be the culprit. The spiral wire casing was quite corroded and it is pretty old. I did wiggle all the connectors I could easily access...
  2. U

    Raypak heater problem

    I'll try that tonight. Thanks for the response. Let me clarify. I bypass the safety circuit by using a jumper then remove the jumper and it stays ignited. I found it odd that a switch would close only because the flame is ignited. That was next up. Thought maybe someone could suggest one of...
  3. U

    Raypak heater problem

    First time poster here and I'm hoping the WOTL can help me. The heater is a Raypak Versa 265B. Now before you go saying it is not worth saving because it is older than dirt bear with me. It all depends on the cost of the repair. I do my own work and am pretty competent when it comes to...
  4. U

    Owned my pool for years but have questions

    Hi everyone. I've owned my 18' round AG for 20 years and although it isn't large the water is just as refreshing as the big public pool. LOL I live in the woods in Northern Lancaster County that create some challenges in pool ownership but all in all it has not been bad. The pool is a...