Search results

  1. N

    Laars Lite 2: Flame Sensor issue

    Oh I should clarify: I am certainly NOT suggesting that I would take out the flame sensor. I'm just trying to make sure that you agree with my above tests, namely that when the flame sensor is plugged it, it is in fact the flame sensor that is shutting the system down, and not some other fail...
  2. N

    Laars Lite 2: Flame Sensor issue

    Okay so update from my end: Installed the new flame sensor and used a wire brush on the various terminals and connection points. I did note that some areas seemed cleaner than others, should I be using some sort of solvent at this point to completely remove the corrosion? As for my testing, I...
  3. N

    Laars Lite 2: Flame Sensor issue

    That seems like a very reasonable suggestion. The new flame sensor just came today, so I'm going to clean the wires as suggested and see how that work out tomorrow. I want to convince myself I'm at least making progress before I sink more money into parts like the valve, as if I end up having...
  4. N

    Laars Lite 2: Flame Sensor issue

    Thanks for the detailed review. I had cleaned a few of the ground connections but hadn't really done any of the others. I'll give all the wire connections a good brushing, along with the various burner attachments when the new flame sensor comes in. Unfortunately the new flame sensor doesn't...
  5. N

    Laars Lite 2: Flame Sensor issue

    Ah that's too bad. Thanks for checking!
  6. N

    Laars Lite 2: Flame Sensor issue

    Various wiring pics. One thing that may be of note is the placement of the ground. Although my tests didn't really find any difference with it's placement, it could go closer to the flame sensor as per the article about flame sensors
  7. PXL_20210822_170224130.jpg

    PXL_20210822_170224130.jpg

  8. PXL_20210822_170308752.jpg

    PXL_20210822_170308752.jpg

  9. PXL_20210822_170319473.jpg

    PXL_20210822_170319473.jpg

  10. PXL_20210822_170356975.jpg

    PXL_20210822_170356975.jpg

  11. PXL_20210822_170406962.jpg

    PXL_20210822_170406962.jpg

  12. N

    Laars Lite 2: Flame Sensor issue

    Pictures of the burner tray, and where flame sensor is supposed to go
  13. PXL_20210822_153241806.jpg

    PXL_20210822_153241806.jpg

  14. PXL_20210822_153249112.jpg

    PXL_20210822_153249112.jpg

  15. N

    Laars Lite 2: Flame Sensor issue

    Having some trouble with my phone pictures right now, but quick update: There is definitely some dampness on the bottom of the unit, which is troubling. A lot of what you are seeing down there is wet insulation that has come off. Regardless, it is cleaned up now. I've also checked all the...
  16. N

    Laars Lite 2: Flame Sensor issue

    Here are the various pictures I've taken to date. Not sure if they help at all. We've got thunderstorm watch for the rest of the day, so I'll snap more pictures when I clean out the burners/orifices. Please let me know if there is anything else that would be particularly helpful when I work...
  17. PXL_20210821_120752283.MP.jpg

    PXL_20210821_120752283.MP.jpg

  18. PXL_20210821_161159759.jpg

    PXL_20210821_161159759.jpg

  19. PXL_20210820_220421586.jpg

    PXL_20210820_220421586.jpg

  20. PXL_20210820_220431968.jpg

    PXL_20210820_220431968.jpg

  21. N

    Laars Lite 2: Flame Sensor issue

    I just checked the gas valve which has a "VR8305H 4013" code on it. I can't find a serial number on the heater itself. The Fenwal unit has catalog number 05-339013-003 and also E0201300, not sure if those can help. I moved into the house in 2014, and the heater looked like it had been used...
  22. N

    Laars Lite 2: Flame Sensor issue

    Thanks for the quick response! I've seen at least two manuals floating around, but this one has the wiring diagram that looks exactly like the one inside the heater: https://shop.solardirect.com/pdf/pool-heaters/gas-pool-heaters/jandy-lite2manual.pdf . Page 7 has the wiring diagram. The...
  23. N

    Laars Lite 2: Flame Sensor issue

    Hello all, I was recently having an issue with my pool heater (Laars Lite 2 - Natural Gas, LD), in that it would ignite, and then turn off w/n 1-2 seconds. After some research, it seemed it might be a faulty flame sensor. I started cleaning it off in place but the contraption with the flame...
  24. N

    Mesh Cover + Plaster Pool

    Dumb question: Is there any worry about the partial drain on a plaster pool for winterization? The mesh cover instructions say to keep the water level at 15-18" below the top, but I'm wondering if there is any issue of that exposed plaster being damaged over time. I haven't seen any issues the...
  25. N

    Pool opening: manual vacuum needed?

    Thanks to both replies. I opened the pool yesterday morning, and pool was surprisingly clean, mostly just worms and a negligible amount of dirt. Polaris and brushing has picked up 98% of it as of this morning, so hopefully one more brushing and vacuum will take care of this. Now I just need...
  26. N

    Pool opening: manual vacuum needed?

    Hello, and thanks as always for all the great info. I did not open my own pool last year but plan on doing so this year. Throughout the season I was able to maintain a clean plaster pool through brushing and a Polaris 360. I have a loop-loc cover so it will be definitely not be spotless when...
  27. N

    Main Drain Cover- Brass Threaded Insert Failure

    Not sure if this helps, but here is a picture of the cover and a picture of the screw/threaded insert.
  28. Screw+Thread.jpg

    Screw+Thread.jpg

  29. Cover.jpg

    Cover.jpg

  30. N

    Main Drain Cover- Brass Threaded Insert Failure

    First off, I absolutely love this forum, you guys have taught me so much on pool and hot tub chemistry. Just put in my donation for lifetime member status. Now for my most recent problem: I noticed one of the screws was protruding from my main drain cover, so I tried to screw it down, with no...