Search results

  1. B

    Kreey krauler skimmer adapter k12932

    I have an ancient kreepy krauler that I have repaired/rebuilt over the years. It is an integral part of my pool maintenance, especially when I fall a bit behind and need more vigorous cleaning. Somewhere along the way, I lost the adapter that screws into the skimmer, (KREEPY KRAULY | THREADED...
  2. B

    Repairing cracks at skimmer/pool junction, and somewhere along intake plumbing (skimmer to pump)

    Been in the house for 20 years, and periodically have had to patch up small cracks around the skimmers as they pull away from the gunite, so I know I have a settling problem. But this time, I keep leaking from somewhere else even after repair I did some pressure testing today by closing off one...
  3. B

    2018 Bleach Prices

    Not only are the new Walmart brand bleach bottles now only 6%, but they are also lower volume, and deceptively so. It used to be 1 gallon, which = 3.78 L or 4 quarts. It is now 0.945 gallons, which = 3.78 quarts. Note the decision to pick a volume so that it equals 3.78 quarts. I believe it...
  4. B

    New champion Century motor keeps throwing thermal overload switch

    I changed it to 240 and all is good. thanks
  5. B

    New champion Century motor keeps throwing thermal overload switch

    I replaced an old champion motor today that had been running well for the 11 summers I've owned the house, with a couple of seal replacements along the way, because it stopped starting unless I gave it a bit of a "jump start" by turning the shaft by hand (brushes?) Rather than tear into it, in...
  6. B

    can this diving board be saved?

    definatelyprefer board, thanks The length appears to be an outlier. This link suggests that such boards should only be used when the U-stand is 24", and mine is not nearly that! http://www.interfab.com/files/2011_tech_guide.aspx
  7. B

    can this diving board be saved?

    My board is a 12 footer, so a six footer wouldn't even get me out over the water! And S.R. Smith only makes them out to 10'. I'll keep looking, but I suspect that the cost will put me in range to start all over if it would make sense space-wise and installation-wise. I'm pretty handy...
  8. B

    can this diving board be saved?

    a few more questions (for now) If a replacement board is needed, is aquaboard my only option, or is the mounting configuration universal, and used by many manufacturers? A recent addition makes the long board inconvenient in using the deck area around it. I see many types of shorter boards...
  9. B

    can this diving board be saved?

    THis diving board was installed prior to our buying the house 10 yrs ago. The bolts got pretty rusted and I removed them (hacksaw) and was surprised to see that the core of the board is wooden, but the rearmost wood has rotted out where water got to it through the bolt holes. The fiberglass is...
  10. B

    Walked out to find my pump running dry. . .

    Just an update, re;laced the bearings and seal. The seal clearly had a small chronic leak. I also gave every bolt on every joint on the infeed side a 1/8th turn, then primed it (filled the prefilter bucket) and it fired right up. I don't know how what I did could have fixed the problem, maybe...
  11. B

    Walked out to find my pump running dry. . .

    Thanks guys. Now I wait for delivery. It will likely be here befor I could have gone out and bought the stuff, unless Leslie's stocks it all. Even then, couldn't get til this wkend. None of the pump/motor maintainance I intend to perform appears related to my original problem. Other than a...
  12. B

    Walked out to find my pump running dry. . .

    Well, I ordered bearings, a shaft seal, a couple of orings, and a bearing puller. I'll get an education in basic motor repair/maintainance, and a tuned up motor to boot, While this is bound to be quite an adventure, I dare say none of this is likely to address my original problem. I do run a...
  13. B

    Walked out to find my pump running dry. . .

    I plan on replacing the o-ringthat seats where the screw driver is going through, at the inlet. The old one got rolled on insertion and is now permanately twisted. It never leaked, though. Anything else I should do while I have it apart? Replace the shaft seals? Replace the bearings (don't...
  14. B

    Walked out to find my pump running dry. . .

    gasket is in, guage is in. You can see the sorry state of the old gasket. Lots o scrapin'. I pulled the motor and everything looks ok. The impeller spins when powered. See anything wrong? I'm beginning to wonder if I have a leak at one of the unions on the feed end, allowing air into...
  15. B

    Walked out to find my pump running dry. . .

    Sent to the store by the wife, and stopped by the pool store (shudder). I picked up a new gasket and a Leslie brand pressure gauge. the gauge fit right in. The gasket's going to take a bit of work, scapping out the old one. The clerk recommended silicone sealant for placing the gasket and...
  16. B

    Walked out to find my pump running dry. . .

    Yeah, but it looks like it could stick all of the way through to the other side, offering support on both sides to pivot around. Having now taken the top off, I see that even if the pin isn't positioned right, the mechanism is not likely to have been unduly stressed. The mechanism is much...
  17. B

    Walked out to find my pump running dry. . .

    forgot to ask, can I access the relevant parts of the valve by removing the screws on top, or will I have to remove the whole apparatus from the top of the filter. Thanks
  18. B

    Walked out to find my pump running dry. . .

    I run my pump for 7 hrs a day using a salt water chlorine generator. I walked out yesterday to find it running dry, and it may have been running dry for a few days. I have lived here for 4yrs and I've never serviced the pumps in any way. I'd appreciate some help trouble shooting. When I fire...
  19. B

    Refractometer and Salinity Measurements are unexpected...

    I stand corrected. My refractometer has both ppt and sg, and agree with your numbers.
  20. B

    "new" pool with . . . anomalies

    Nah, four returns. I just didn't draw it that way. The return in the deep end is pointed at the MD Any thoughts on how to proceed?
  21. B

    "new" pool with . . . anomalies

    What am I? A freakin' idio. . . Oh. . . Well, yes :oops: The skimmer furthest from the pump has two holes. So this should be the plumbing I remain reluctant to unclog the MD. I think I'll wait till the fall and have a pro take a looka t it. How crucial is the MD to overall pool...
  22. B

    "new" pool with . . . anomalies

    I have played with the valves at the pad and each definately serves a different skimmer. There is no evidence of a history of a third pipe at the pad (learning the lingo). Any further thoughts on trouble shooting this? The obvious answer is just to unplug it and see how it goes, but I...
  23. B

    "new" pool with . . . anomalies

    So the second hole in the skimmer box would connect to the MD and go to the pump separately from the main skimmer line, so I should have three pipes (MD/skimmer1, skimmer1, skimmer2) feeding the pump, but I have two (skimmer1, skimmer2). How would you then decrease the relative flow from the...
  24. B

    "new" pool with . . . anomalies

    I have two skimmers and four returns, not counting the polaris return. The pool is about 38000 gal, 20x40", about 8 ft deep at deepest. Both skimmer boxes have only one hole. I kinda figured that the main drain and one of the skimmers were/are plumbed together, but how would you regulate...
  25. B

    "new" pool with . . . anomalies

    I bought a house that has a pool last January. Other than the auto top off not being connected, the pre-purchase pool inspection was good. I have been undoing the prior owner's "home improvements" with great frustration. I didn't pay much attention to the pool getting settled in withe new...
  26. B

    Difference btwn new/old models of Aquarite & vendor question

    I just received an aquarite XL 40K from poolpartsonline, with "XL" apparently indicating the inclusion of the wiring kit: http://www.poolpartsonline.com/p-509-aq ... rator.aspx Later, I see that they also sell "Aquarite 2009", wherein you select the chlorine generator System, Turbo cell, and...
  27. B

    Refractometer and Salinity Measurements are unexpected...

    I am also a reefer and I'm putting in my first SWG. I love this site!! I think I've got this figured out, as I'm inclined to use my refractometer as well. The refractometer gives the specific gravity, in (grams of sample) / (grams of pure water), or grams/grams, so unitless. Water with...