Search results

  1. J

    Pentair Ultratemp Cycles on/off when pump is off

    Update for internet search posterity: Control board replacement did not fix the issue. Tech came back and replaced the pressure switch and it is now resolved. Some other notes: the pressure switch appeared to be leaking as the rubber cover over the switch was filled with water. I watched them...
  2. J

    Pentair Ultratemp Cycles on/off when pump is off

    Thanks for the response, TKpoolOH. I checked and my heater does not have the AutoSet feature. I contacted Pentair and they sent a tech out who diagnosed the issue as a bad control board which he replaced under warranty. The board is evidently associated with the pressure switch, but the switch...
  3. J

    Pentair Ultratemp Cycles on/off when pump is off

    Yes, I have turned the heater off. Thank you very much for your help!
  4. J

    Pentair Ultratemp Cycles on/off when pump is off

    Thanks for the response! The heater is above water level (in-ground pool). I will follow up on the pressure switch possibility, but in general, having a heat pump installed with no automation and using it the way I'm using it is OK?
  5. J

    Pentair Ultratemp Cycles on/off when pump is off

    I've had a Pentair UltraTemp for a little over a year. It works fine but when the filter pump is off the heat pump periodically turns on for a few seconds and then turns itself off. I started noticing this at the end of last season...not sure, but I don't think it did this when it was first...
  6. J

    Help with Pentair VSF and Solar

    The VRV is located on the output side of the top most panels. There's definitely no water leaking from the VRV and I have no air bubbles coming out of the returns so I think I'm good for now. What about the tech's method of turning up the speed on the pump until water came out of the VRV...
  7. J

    Help with Pentair VSF and Solar

    Thanks very much for your response. I did some more searching and reading yesterday and came across the suggestion on how to check if the panels are fully primed, by running the pump at a given speed and then turning it up higher to see if any more air comes out of the returns. I had been...
  8. J

    Help with Pentair VSF and Solar

    Hi all, I have a recently installed Pentair Intelliflo VSF pump and a solar heating system, and some questions about dialing in the variable speed pump to properly run the solar heat. I thought I had a good idea of how to do from searching these forums but the tech from the solar company...