Search results

  1. M

    Pool flow alarm... not pool alarm for kids

    Great idea Question... Would you put the flow switch before the pump, after the pump or both? I plan to tie this all into the house security at some point along with installing a wifi electrical breaker so I can shut down at least the pump if not the entire system remotely. Thanks
  2. M

    Pool flow alarm... not pool alarm for kids

    I ran into a problem a couple of days back with my pool equipment. The pressure side of the pump to the filter developed a leak and drained out enough water so the skimmer ran dry and the pump started to squeal bad enough that a neighbour came over to see what all the commotion was. I am away...
  3. M

    When to change out your pool filter

    The question I had was in regards to the actual white pleated filter in the housing. Thanks
  4. M

    When to change out your pool filter

    I am a new owner of an old inground pool with little history. I am wondering how often the large pool filter will need to be replaced. I am thinking of starting with a new filter and would like to know if you get more than a year out of them. The unit is a Pentair CC-150 filter.
  5. IMG_1262.jpg

    IMG_1262.jpg

  6. M

    "SLR Sensor Open" code

    Good point. I will check the wiring as I hate using crimps and try to solder wherever possible. Thanks
  7. M

    "SLR Sensor Open" code

    You have confirmed my suspicion and thanks for the quick response
  8. M

    "SLR Sensor Open" code

    I have a rooftop solar panel and a Goldline Hayward Aqua Logic system. My first question is... is the below error coming from the pool water temperature sensor or the sensor up on the roof? My manual says three sensors and I have confirmed are in place. - Water sensor - Temperature sensor -...
  9. IMG_1244.jpg

    IMG_1244.jpg

  10. M

    Help to identify Pentair check valve

    1poolman1 Thanks for the help. I will go ahead and order a replacement
  11. M

    Help to identify Pentair check valve

    Thanks but I need to ask. The PVC plumbing I have is all 2" and it appears the 270119Z is for 2.5"-3" Am I correct in my assumption?
  12. M

    Help to identify Pentair check valve

    I have one check valve which is used to keep the spa water from syphoning into the pool at the end of the day. I am not sure if the valve is part number 263042Z or 270119Z. Anyone have a guess? Thanks
  13. Check Valve.jpg

    Check Valve.jpg

  14. M

    Spa not working after hours

    I appreciate the reply and it looks like I solved the problem. Yesterday and this morning it was a little too dark to see what was happening with the valves. It turns out the return valve was working fine switching between pool and spa. The suction valve was only on pool and would not swing over...
  15. M

    Spa not working after hours

    We have an Aqua logic ps4 and everything seems to work properly during the normal daily run times. When I select spa the spillover stops and the spa heats. The issue I am having is when I select spa after the normal run time, let’s say 9 pm the pool does not go into spa mode. The spa indicator...