Search results

  1. CBA-PoolDad

    New to TFP - SFS error on Mastertemp 250 :(

    Quick question: what is the TFP store?
  2. CBA-PoolDad

    New to TFP - SFS error on Mastertemp 250 :(

    Replaced the sensor this morning…heater is working again. Thanks everyone!
  3. CBA-PoolDad

    New to TFP - SFS error on Mastertemp 250 :(

    Thanks so much! This was interesting: when I put the SFS back together and tried the heater once more just to see, the same thing happened but I got an E05 error code for the first time. Every other time I just had the red light underneath the panel.
  4. CBA-PoolDad

    New to TFP - SFS error on Mastertemp 250 :(

    Hahaha…oops! Thank you
  5. CBA-PoolDad

    New to TFP - SFS error on Mastertemp 250 :(

    We always have the number “1”
  6. IMG_2094.jpeg

    IMG_2094.jpeg

  7. CBA-PoolDad

    New to TFP - SFS error on Mastertemp 250 :(

    Like this? I’m not getting any change of number on the multimeter
  8. IMG_2093.jpeg

    IMG_2093.jpeg

  9. CBA-PoolDad

    New to TFP - SFS error on Mastertemp 250 :(

    I don't have a multimeter, but I could ask around some friends
  10. CBA-PoolDad

    New to TFP - SFS error on Mastertemp 250 :(

    Thank you for your reply - super helpful!! and it sounds like I will start here, esp. since it's a pretty cheap part to replace :)
  11. CBA-PoolDad

    New to TFP - SFS error on Mastertemp 250 :(

    It starts out at air temp, then goes up to 100s, 200s, 300s, then 400s and then off. It doesn't bounce around too much really, and only takes about 30 seconds to turn off because of high 400s
  12. CBA-PoolDad

    New to TFP - SFS error on Mastertemp 250 :(

    Thank you so much for the information. I ran the heater without the thermal regulator in place, and it went up to 480 degrees super quickly, so it looks like my next step is to replace the stack flue sensor and then try again!
  13. CBA-PoolDad

    New to TFP - SFS error on Mastertemp 250 :(

    Question: is it safe to do this? I'm just not smart enough about this system :) Also: can you run the heater for like a few days without the thermal regulator in place? Or maybe if the SFS is bad, it wouldn't work anyways?
  14. CBA-PoolDad

    New to TFP - SFS error on Mastertemp 250 :(

    - I think that is just a little water that was leaking from the cell - Filter pressure: I've back flowed and get no errors about high pressure, but unfortunately my little gauge broke so I don't know for certain :( - Pump speed is at 50 GPM when running heater
  15. CBA-PoolDad

    New to TFP - SFS error on Mastertemp 250 :(

    Hi James, Thanks so much for the replies! Here's some more info: - New thermal regulator opens under hot tap water from kitchen faucet (I honestly didn't measure 120 degrees, but it definitely opens...my old one was corroded and green) - Here's a picture inside regulator pipe:
  16. adams reg pipe.jpeg

    adams reg pipe.jpeg

  17. CBA-PoolDad

    New to TFP - SFS error on Mastertemp 250 :(

    Hi all! I'm wondering if anyone could help point me in the correct direction. Here's what I have so far: - 3 year old system has been working well until now (no signs of mice inside) - Heater ignites, and I get an SFS error about 15-45 seconds later bc it was quickly heating to over 400 degrees...
  18. IMG_2077.jpeg

    IMG_2077.jpeg

  19. IMG_2075.jpeg

    IMG_2075.jpeg

  20. IMG_2076.jpeg

    IMG_2076.jpeg