Search results

  1. E

    Too much chlorine?

    My ware testing kit says I have 45 ppm
  2. E

    Too much chlorine?

    I recently installed a new cell (RC35/22) in an Autopilot system and the chlorine levels have been high for approx. 3 weeks. I have been gradually reducing the purifier power and for a week its been running at 30% but chlorine levels show at 5 ppm (total) and 4.5 ppm (free). Diagnostics state...
  3. E

    Need to get a new Autopilot Cell for my system: Questions

    I called Autopilot regarding a persistent Error "Clean/Check Cell" and it looks like after 2 years my SC-36 cell has failed. The system tests states "Cell=31V, 3.7A", so the tech at Autopilot indicated that the power supply is OK but that the cell has likely failed. I am thinking on doing this...
  4. E

    Help needed with Autopilot Digital DIG 220: check/clean cell

    Re: Help needed with Autopilot Digital DIG 220: check/clean I have exactly the same problem. I think you will have to replace the power supply and its like $500.00. I am waiting for the pool service people to come tomorrow with the bad news. I am considering changing brands to something a...
  5. E

    Autopilot Message: "Clean/Check Cell"

    Hi, I am new to this forum, so I hope someone can help me. I have the Pool Pilot Digtal 220, bought several years ago. The cell was relaxed about 2 years ago. Last week I got the red light flashing error "Clean/Check Cell", so I cleaned the cell (it was relatively in good shape, just a little...