Search results

  1. K

    I have a leak at my pool filler.

    Darn, unfortunately the water did not rise. The leak is going into the ground. Maybe I can come up with something clever, like running a new line inside of the old line, and putting a different kind of valve on it.
  2. K

    I have a leak at my pool filler.

    Thanks for the reply. Good point. I'm not sure the water is going in the canister/pool. I'll do that test tomorrow and find out.
  3. K

    I have a leak at my pool filler.

    I installed the Fluidmaster, since that's what was there when I bought the house. (That's what I've always replaced them with. Whatever Lowes has had.) I read the links you sent. Seem like the only differences between the two is the pressure restrictor for eliminating water hammer (and the...
  4. K

    I have a leak at my pool filler.

    Hi. I have a pool with an autofill, the style where it's uses a regular Fluidmaster toilet tank filler, installed under a cover, on the deck near the pool. Overall it's always worked well. I've replaced the filler 3 or 4 times over the years when it started leaking or acting up. Several...
  5. PXL_20231204_033105104.jpg

    PXL_20231204_033105104.jpg

  6. K

    Pool Heat Pump Leaking Freon

    Thanks for the input, and the info on the copper/titanium transition. Exactly, what will be next, the compressor, or a leak somewhere else? It's hard to justify putting too much money into a 9yo unit.
  7. K

    Pool Heat Pump Leaking Freon

    Yes, I think it does, if the titanium part is the cause of the failure. (i.e. If the titanium component of the heat exchanger fails, they'll replace the entire heat exchanger ($2k). But if for example the PVC component of the heat exchanger fails, then it's not covered by warranty.) What's...
  8. K

    Pool Heat Pump Leaking Freon

    I have a 9 year old Hayward SUM8TA 140k BTU pool heat pump that is leaking freon. The tech who was recharging it spotted the leak. The titanium part of the heat exchanger is still under warranty, but nothing else. No labor warranty. Charging the unit is about $500, and last time it lasted...
  9. HeatPump leakin location.jpg

    HeatPump leakin location.jpg

  10. K

    Aqualink questions

    Thanks for the manual link. Thanks for the explanation. Yep, HermanTX was correct.
  11. K

    Aqualink questions

    Thanks for the idea. (I've been doing other more urgent projects, so just got back to this.) Bingo! Speed 3 is assigned to the Aux called Pool Light. To verify what this means functionally; if Pool light is activated, then the pump turns on and runs at Speed 3, correct? Because that is...
  12. VSPSpeedSetup.png

    VSPSpeedSetup.png

  13. K

    Aqualink questions

    To clarify; I've never used the one touch screen, nor programmed it. Perhaps someone else programmed it. I'm using the button on the Home screen, or the schedule. Where is the Equipment screen?
  14. onetouch.png

    onetouch.png

  15. Homepage.png

    Homepage.png

  16. K

    Aqualink questions

    Thanks for the manual. That looks better than the one I had found. I'll read through.
  17. K

    Aqualink questions

    Thanks for the reply. The light was wired into a relay that was plugged into Aux1 for control. Aux1 was labeled "Pool light". Then in the schedule, I programmed the "pool light" to go on at night. Also if I just pushed the Aux1 button on the physical controller panel, it would go on. And...
  18. IMG_20220604_123119047.jpg

    IMG_20220604_123119047.jpg

  19. K

    Aqualink questions

    I have a pool with an Aqualink RS power center with the iaqualink internet connection. I'm a pretty handy guy, but this controller frustrates me. It's not configurable to the degree I'd like, and it does some things I do not understand. I have a few questions I was hoping to get help with...
  20. JVA assignment.png

    JVA assignment.png