  1. bradgray

    Looks like I need a new SWG

    Just to clarify, the item that determines if it's salt-ready or not is a transformer. You can't see the transformer unless you open the high voltage panel, but a giveaway is that small rounded terminal underneat the front left corner of your EasyTouch. It looks a lot like a MIDI or MIC cable port.
  2. bradgray

    Proper check valve for elevated Spa.

    I think this good information in general, but the OP was asking about check valves, not diverters with CVs built into them. It was described as a 'flap' and there was no reason to suspect it wasn't a conventional CV. We can ask OP to clarify if they have confused their check valve with a...
  3. bradgray

    sacrificial anode for auto cover tracks in swg pool

    Not really clear why the auto cover tracks are your priority. Tracks are easily replaced inside the encapsulation if they get damaged. Anode won't protect these - they aren't submerged in the pool water unless you have a negative-edge pool. A sacrificial anode will be placed in the plumbing...
  4. bradgray

    Proper check valve for elevated Spa.

    I'm not familiar with any check valve manufactured with holes. This defeats the purpose of a 'check' valve.
  5. bradgray

    Planning on rebuilding hot tub siding and have a question about it.

    You can snug the bowed slats back to the backing with trim screws. Glue is always temporary. You can add backing where it's lacking support. You can refinish the panel as well. Paint will last as long as the quality of the paint and prep permits. I'm looking at plastic oils or heat treatments...
  6. bradgray

    Looks like I need a new SWG

    Is your Easytouch salt ready? Easiest way to tell is to look for the small black 4-pin connection on the bottom front-left of the panel. If so, IntelliChlor is a logical choice. If not, you will need to purchase the power center for the cell. Adds a measurable cost. You'd then have to Rs485 to...
  7. bradgray

    Landscaping

    Our area is mild and we have dozens of 'evergreen' trees, and they are deceptively high maintenance. Rather than total leaf loss 1 month of the year, you will find them dropping the entire year in small amounts with emphasis in the spring. Much like human skin - we never 'lose' our skin, but we...
  8. bradgray

    Need help with Lighting

    Ideally you will terminate in a junction box. Jbox will then connect to Xfmer via carflex. Xfmer carflex to IAqualink. Bonding wire from Jbox to IAqualink bonding lug. It's best to airgap the conduit from your panel.
  9. bradgray

    Help Please - Aux Relays Not Working

    A picture behind the deadfront panel where the breakers are located, will help us. Is you pump wired to a relay? Or direct to breaker? Single SPD or VS? Is your heater wired to the same relay as your pump? Is it on a relay at all? Have you confirmed voltage on the Line side of the relay for...
  10. bradgray

    Pump Losing Pressure - Need Additional Ideas

    You most likely have a leak on the suction side, as many have suggested. A worn or loose impeller may fail to 'build' prime but it sounds like it draws the initial gallon through, it just chokes on air rapidly thereafter. You don't have any valves, so this really only leaves the items you've...
  11. bradgray

    Using a dust collector (instead of shop vac) installing new pool liner.

    I would stick with a shop vac. Why do you wish to use your dust collector? Mine is massive and clunky and built into the shop walls. If you could get yours to the pool, I would be worried about the higher CFM preventing me from managing the wrinkles in time.
  12. bradgray

    Valve replacement and possible replumbing advice?

    sarcasm? You're not wrong categorically and this isn't a criticism. Just sharing some examples of when I wished it had been 2 or 3 valve position mistakes before someone blew it up, instead of 1. Yes, this. All that needs to occur is for the pins/posts on the Pentair valve to break or go...
  13. Screenshot_20250101_222941_Chrome.jpg

    Screenshot_20250101_222941_Chrome.jpg

  14. Screenshot_20250101_222557_Chrome.jpg

    Screenshot_20250101_222557_Chrome.jpg

  15. Screenshot_20250101_222608_Chrome.jpg

    Screenshot_20250101_222608_Chrome.jpg

  16. Screenshot_20250101_222629_Chrome.jpg

    Screenshot_20250101_222629_Chrome.jpg

  17. bradgray

    Valve replacement and possible replumbing advice?

    I understand what you're proposing. Bear with me though... I'll have to find the photos in my system, but I've had at least two 3-ways in the last year misused in a way that reveals the weakness in that design. One that burned up a single speed pump and another that was on a return as a...
  18. bradgray

    Valve replacement and possible replumbing advice?

    If I'm you, I'm putting a 2-way valve as the first piece after you cut the intake pipes. In other words, giving SK, MD and VAC their own vertical 2-way. I do not personally like the 'either or' layouts some builders use. The theory is that is saves on material and reduces the odds the pump is...
  19. Screen Shot 2024-12-31 at 9.34.38 AM.png

    Screen Shot 2024-12-31 at 9.34.38 AM.png

  20. bradgray

    Valve replacement and possible replumbing advice?

    Strangely the system didn't notify me of the tag but I stumbled on this one anyway! I agree with all suggestions. I would start with PVC weld if they are hairline cracks. I really like FUSION by Oatey for all our retrofit plumbing. It's great for sealing suction leaks as well because it's...
  21. bradgray

    Autocover owners - Should we be concerned about the lid pavers moving / falling?

    You can also run/affix parallel aluminum strips across the brackets so that there is no potential for shifting of a tile that would then drop and contact the cover. We've done this for many VR homes that get rough foot traffic on them. Depending on how tight the pieces are installed, some...
  22. bradgray

    Pentair not allowing Spa heater to turn on

    On outdoor panel: Settings > Advanced Sys Config > Installation Setup > Heaters Look at your heater and make sure it's assigned to Pool/Spa and not just Pool.
  23. bradgray

    Heating attached spa in the winter?

    What Allen said. Everytime you cross that bridge, you'll get acidic condensate. So cross that bridge as infrequently as possible. And as you stated, never run it below 70 and maintain in that range. Good way to lose your warranty and need a new heater.
  24. bradgray

    OMNI PL Strange Error

    The schematic above may not match your Omni, FWIW. Lets get clear on the exact error as James suggested. All your temp sensors are on the same terminal block. So I'd start there looking for loose connections. Image below may be a closer match to your panel if it's a few years old. Center...
  25. bradgray

    Pentair mastertemp 400 shutting down after hitting 289

    Power cycle your heater if you haven't already. Best case, your membrane is sticky and it was mashing buttons on you. If the panel continues to give you the same trouble, you may be looking at a new PCB in your future. Could be membrane only but in my experience the board goes before the...
  26. bradgray

    Pump not priming full on any speed

    +1. Same observations. It's also not uncommon even for Intelliflo3 and several Jandy pumps (mostly ePump and FloPro) to agitate near the lid but not make contact in certain setups.
  27. bradgray

    My Intellichem Controller is driving me crazy. Never has worked as well as it should since installed in 2022

    Absolutely +1 to Alan's advice. Let us know if you need help doing that.
  28. bradgray

    Pentair Clean & Clear 100 Core Broke and Stuck

    PoolStored is correct. It generally comes out without much argument. In the case where the base gets jammed with sand, the core can detached from the base and the tabs snap off. The base is not glued in there. You may just have to negotiate it or try spraying water around the perimeter to...
  29. bradgray

    Pentair Mastertemp 400 SFS repair

    Just to clarify, are you talking about the female nut internally welded to the flue?
  30. bradgray

    Lost Connection to both pumps

    No, clients wont receive anything if it's parts. We will leave you with the new serial # if it's a whole good, but that's it.