Search results

  1. K

    2-speed spa motor stuttering when starting high speed

    Unfortunately I couldn't find a replacement switch. I did a lot of searching and one spa guy even said that these cheap XL type pumps don't have replacement parts. I finally gave up and ordered a new pump/wet-end for $200 and it works great. LOL Thanks again for all the help.
  2. K

    2-speed spa motor stuttering when starting high speed

    I cleaned the contact with the emery cloth and then reassembled the motor. Unfortunately the problem didn't go away. I'll start looking for a replacement switch. Thanks to everyone that helped me work through this problem. I've learned a lot!
  3. K

    2-speed spa motor stuttering when starting high speed

    The motor is about 2 years old.
  4. K

    2-speed spa motor stuttering when starting high speed

    Ok, I'll try that. Do you think something needs to be adjusted so it doesn't happen again? Or is there a lot of leeway in the switch/governor and this was just a fluke?
  5. K

    2-speed spa motor stuttering when starting high speed

    Looks like the high speed contact is burned. It is definitely different from the other contacts. Is there some way to clean the contact or do I need to buy a new switch?
  6. IMG_20210625_174550767_Easy-Resize.com.jpg

    IMG_20210625_174550767_Easy-Resize.com.jpg

  7. IMG_20210625_173922626_Easy-Resize.com.jpg

    IMG_20210625_173922626_Easy-Resize.com.jpg

  8. K

    2-speed spa motor stuttering when starting high speed

    Yes, both springs are on the governor. Yes, the large washer moves along the shaft. You can see in the picture with my thumb that the washer is being pushed and the governor(?) opened.
  9. K

    2-speed spa motor stuttering when starting high speed

    My easy fix of replacing the capacitors didn't work for long. I've opened up the motor to get a look at the centrifuge switch and it's unclear what to do next. Are there any tests I can do? Maybe just lubricate the switch?
  10. IMG_20210625_105143393_Easy-Resize.com.jpg

    IMG_20210625_105143393_Easy-Resize.com.jpg

  11. IMG_20210625_103634901_Easy-Resize.com.jpg

    IMG_20210625_103634901_Easy-Resize.com.jpg

  12. IMG_20210625_103641064_Easy-Resize.com.jpg

    IMG_20210625_103641064_Easy-Resize.com.jpg

  13. IMG_20210625_105000174_Easy-Resize.com.jpg

    IMG_20210625_105000174_Easy-Resize.com.jpg

  14. IMG_20210625_104731914_Easy-Resize.com.jpg

    IMG_20210625_104731914_Easy-Resize.com.jpg

  15. K

    2-speed spa motor stuttering when starting high speed

    It turned out to be an easy fix. I replaced both the run (25uf) and the start (50uf) capacitors and the problem went away. If the issue happens again I'll take a look at the centrifugal switch. Thanks for all the help!
  16. K

    2-speed spa motor stuttering when starting high speed

    I'd never heard of a centrifugal switch before, but I watched a youtube video on them and think I can find and test it. Thanks!
  17. K

    2-speed spa motor stuttering when starting high speed

    I'll take out the two capacitors (I assume one is the start and the other is the run capacitor) and test them. I may just replace them as they are not expensive. Taking apart the motor/pump is more complicated but I'll try that next if necessary. Thanks!
  18. K

    2-speed spa motor stuttering when starting high speed