  1. Vrh

    Gulf Stream heat pump

    Yes the HP side checks out.
  2. Vrh

    Gulf Stream heat pump

    What I see.
  3. 8F67B6C5-86A6-4A91-9003-7A1F88EBBFB1.jpeg

    8F67B6C5-86A6-4A91-9003-7A1F88EBBFB1.jpeg

  4. 83D989BE-916F-4020-9E1B-7EB9968AD8E0.jpeg

    83D989BE-916F-4020-9E1B-7EB9968AD8E0.jpeg

  5. 23EFA150-8955-496E-81CD-998F61F02ADF.jpeg

    23EFA150-8955-496E-81CD-998F61F02ADF.jpeg

  6. Vrh

    Gulf Stream heat pump

    Also from the tech, “ I thought that maybe this would be an issue with our circuit board so I did replace it. I also replaced the basil on the front so you had better action on your buttons now. Even after replacing the board, the condition still exists. The board is the only component if it...
  7. Vrh

    Gulf Stream heat pump

    I am about to check this out. I am unclear as to how to manually open and close the circuit.
  8. Vrh

    Gulf Stream heat pump

    No, this is not normal, the tech states it does not happen when disconnected from the automation.
  9. Vrh

    Gulf Stream heat pump

    He states, “ basically, when the low-voltage wire coming from automation to my heat pump is disconnected, the heat pump works as designed.”” When l reconnect it, it starts to make the countdown skip and restart repeatedly.”
  10. Vrh

    Gulf Stream heat pump

    I had the manufacturer out, finally, ththey went over the unit and stated it works as designed. looks like the issue is with my automation. Is there any way that the mother board on the aqua logic can be troubleshooted?
  11. Vrh

    Gulf Stream heat pump

    Ok thanks, will do.
  12. Vrh

    Gulf Stream heat pump

    FYI this countdown issue is new...not part of the original problems.
  13. Vrh

    Gulf Stream heat pump

    Yes I can see it. yes the pump is running. pool was heating ok today after I reset the lockout. Switched over to spa and the heater has gone back to repeat countdown mode, stops at 87 reverts back to 120. This goes on until I power off the heater.
  14. Vrh

    Gulf Stream heat pump

    Gulfstream 2 times told me that they sent work orders for someone to come out to look at the heater. after waiting for their call 2 weeks each time I called them and they said they do not service my area. The company pinchapenny pool who sold the unit no longer takes my calls. I was patient the...
  15. Vrh

    Gulf Stream heat pump

    2:30 update heater fan OFF , countdown started, 120. Reverts back to 120 in the mid 80’s . This is continuous.
  16. Vrh

    Gulf Stream heat pump

    P15: having a hard time understanding valve 4. p27: configurations heater 1 — enabled name— heat pump cooldown—disabled heater1 extend—disabled heater 2— disabled
  17. Vrh

    Gulf Stream heat pump

    Not sure where to find my aqua logic version. I have to clear the heat pump WATER FLOW LOCKOUT manually on the heater. I have not touched any of the wiring , the heat pump was installed during my escrow on the home purchase and under warranty.
  18. Vrh

    Gulf Stream heat pump

    8am-6pm
  19. Vrh

    Gulf Stream heat pump

    Aqua logic one page at a time. Being new to pools, I’m having a hard time understanding #1. On page 10. I have only one heat pump (heater 1) and heater 2 is disabled. im not sure what else has to be programmed and I am confused as to reference to Valve 4.
  20. Vrh

    Gulf Stream heat pump

    My circulation pump is Jandy pro series, flo pro FHPM 1.5 one speed. New heat pump Gulfstream HE110-R-A
  21. Vrh

    Gulf Stream heat pump

    Thanks, Allen, I am about to look at the manual. Quick update so I don’t forget. 1pm...pool is up to temperature. heater light off on aqua logic. Heater fan still running but condensation appears to have stopped.
  22. Vrh

    Gulf Stream heat pump

    Allen, ok here is the mystery to me. This morning prior to turn on of the system, the WATER FLOW LOCKOUT was on the heater screen. I can’t understand what would cause this.
  23. Vrh

    Gulf Stream heat pump

    Allen, my heater always displays no flow after the pump turns off. I have never seen water flow HP. Filter is clean. I don’t know how to check the flow rate, but I assume it is ok. perhaps the HP tried to turn on prior to the pump? I don’t know as I checked it after the pump was turned on. HP...
  24. Vrh

    Gulf Stream heat pump

    This morning the heater was on WATER FLOW LOCKOUT, I reset, pool heated to temp and the heater turned off. Checked the heater shortly afternoon and saw that a countdown had started, it repeats the countdown from 120 to the high 80’s continually. Thoughts?
  25. Vrh

    Gulf Stream heat pump

    Ok, I loaded the factory settings on the heater. I will let you know what happens.
  26. Vrh

    Gulf Stream heat pump

    Ok, after reading the article, I think I get it. I am going to turn the heater controls to max then set my automation to the desired spa and pool settings. This should solve my problem, correct? I care because i have a multi (3 )generation home ranging from 8 to 70. I travel and want the...
  27. Vrh

    Gulf Stream heat pump

    I have an aqua logic automation heat pump is 7 months old, always had this problem but I never realized it. automation works fine with all else. Hp heats well. i want the heat pump to correctly Id pool vs spa. I have a notion that it was not installed properly or not comparable with aqua logic...
  28. Vrh

    Identifying fountain light for replacement.

    Thanks James. I appreciate the help.
  29. Vrh

    Gulf Stream heat pump

    Hi, I have a gulfstream heat pump on my pool and spa. It is still under warranty but I am getting no help from the company. It does not seem to be syncing with my automation. It has my pool and spa mixed up on its display and may have additional issues. It does produce heat so that’s not the...