Search results

  1. E

    Small leak on iChlor30

    absolutely. takes me back to the days of adding "overhaul in a can" to a bad engine to get the last few miles out of it
  2. E

    Small leak on iChlor30

    I did remove the cell to inspect but the crack is not visible. it seems the leak is coming from under the flow sensor mounting bracket (not sure what to call it) or between that black bracket and the cell casing. I like your idea of taking Plast-Aid to that entire section to see if it helps...
  3. E

    Small leak on iChlor30

    hi. I did take off the flow sensor and re-tefloned it. however, the leak is actually coming from the under the black part of its casing where the flow sensor screws into. so it may be a crack in the casing itself :-(
  4. E

    Small leak on iChlor30

    excellent. thanks for this...
  5. E

    Small leak on iChlor30

    hi, I have a small leak coming from the top of the SWG (see picture). there's a plastic nut (~5/8" it seems) below the cabling (not seen in picture). I believe it's the flow sensor. does anyone know if this can be tightened to help with the leak? thanks
  6. IMG_5659.jpg

    IMG_5659.jpg

  7. E

    2025 TFP Donation Campaign

    done. great site and very valuable resource. well-worth the donation. thanks!
  8. E

    Cracked screw mount for valve

    Similar to JB. This is a one-time solution. If I need to replace a seal, I probably wouldn’t be able to seal it right again. Not a bad idea. I also thought of rigging a pipe band strap if needed.
  9. E

    Cracked screw mount for valve

    i figured. and you're right, i'll try the JB weld or super glue/cement approach as last resort. but that would be the last fix since upon removing the screw the JB weld would break. thanks
  10. E

    Cracked screw mount for valve

    Hi. This is a long shot - is there a fix or “hack” to address this crack? It’s not leaking even though it’s on the return side (more pressure), but I’m sure it’ll finish breaking at some point. I really want to avoid replacing the valve (no pipe slack). Thanks.
  11. IMG_2024-07-08-082930.jpeg

    IMG_2024-07-08-082930.jpeg

  12. E

    My Pool Automation Adventure

    Hi. First off, 1000 times “thanks” to all the feedback/answers I’ve received from this forum. While this may come across as a low-key brag, I’m offering my experience with my own pool automation results. I wired an ESP32-based Pool Controller, and using ESPHome and Home Assistant (HA), I exposed...
  13. E

    Rotate valve cover.

    perfect. thanks!
  14. E

    Rotate valve cover.

    But the built in limits only apply with the manual levers. the actuator sits over those. I agree with the other comments that if the actuator were to fail somehow and block the inlet (in my case), the pump would run dry. if this was the return line, you're right, the risk is deadhead if the...
  15. E

    Rotate valve cover.

    sorry, really not following. let me try again. currently the valve lids (not covers as i mentioned above) are positioned in such a way that the actuator would line up is Figure I. If i mount them like that, the actuators wont fit next to each other. so i need the mounting holes to be lined...
  16. 1718554538511.png

    1718554538511.png

  17. E

    Rotate valve cover.

    i have the manual. what i'm asking is if it's ok to rotate the valve covers so that 4 mounting screws are positioned differently. I'm wondering if there's a reason why the cover is in a certain position for integrity, or it doesn't matter. Using this image from the manual, i need the 2...
  18. 1718553616037.png

    1718553616037.png

  19. E

    Rotate valve cover.

    Hi. I want to install valve actuators. Currently, the valve covers are positioned such that the actuators would be horizontal (see picture). I need them to be vertical (see picture) so they will fit. Is rotating the valve cover (see picture) a problem? Thanks.
  20. IMG_2024-06-16-090139.jpeg

    IMG_2024-06-16-090139.jpeg

  21. IMG_2024-06-16-090115.jpeg

    IMG_2024-06-16-090115.jpeg

  22. IMG_2024-06-16-090103.jpeg

    IMG_2024-06-16-090103.jpeg

  23. E

    Adding temperature probes

    i actually bit the bullet and drilled the pipe. i did drill in a place where if i messed up, i had enough pipe to install a coupling to fix. thanks!
  24. BEA20363-558F-4FA7-BDEA-50281F050562.jpeg

    BEA20363-558F-4FA7-BDEA-50281F050562.jpeg

  25. E

    Adding temperature probes

    This is the amount of pipe I have to play with. If I drill and pipe gives, I only have one shot to fix easily. And the fix would involve a coupling and very likely look like adding the 2” Tee. So I may just go with that from the get go. Thanks.
  26. E

    Adding temperature probes

    Not a bad idea. I might go this route but I have to get threaded probes.
  27. E

    Adding temperature probes

    It’s the 10kohm temp probes like these: https://a.co/d/4Qxm2Qy I built a pool controller (pump start, filter monitor, etc) and want to see the water temp. The probes already work in my controller, I just haven’t installed them in the pipes…
  28. E

    Adding temperature probes

    hi. i'm wanting to add temperature probes to the suction (inlet) and return (outlet) lines. the plumbing (PVC) is ~12-14 yrs old. how risky is it to drill 3/8" holes into the 2" pipe? i'm concerned i may crack the PVC during drilling due to age and direct exposure to sunlight all this time...
  29. E

    iChlor 30 Effectiveness