Search results

  1. S

    air leak repair

    I was adding teflon tape to the pressure gauge with the multi port set to closed. I guess I took too long, because the filter started dumping all the DE out of the returns. Am I doing something wrong by servicing the pump/filter with the pump off and setting multiport to closed? This might be...
  2. S

    air leak repair

    Not sure what you mean, but I found the gasket! Not sure how to describe it, but there was already a gasket there and it looked like it was part of the pump, so i didn't notice it. Turns out the current gasket is fine and replacing it with new ones did not make a difference. I guess my pump is...
  3. S

    air leak repair

    Here is a video on the union I have, the sp3200 Ignore whatever that guy is doing for a different pump. Just using the video as example of what I have since it looks exactly the same. Note, I bought the spX3200 union gasket. Maybe that X means it's for a different union? I don't see any...
  4. S

    air leak repair

    I checked and the union says it's sp3200un cpvc. I bought the gasket sp3200ug but I don't know how to seat it. On post #10 above you can see pictures. Only way I could make it fit was in between the two connections, which is not sitting on anything. If I put it inside the female screw cap, then...
  5. S

    air leak repair

    Tried the bubbles and didn't notice anything. Also tried a hose on the possible leaks to see if the pump basket would get full of water and nothing happened. Tried adding plumbers tape the the suction union and pump drain plugs and nothing happened. I Was thinking the pump is looking okay to...
  6. S

    air leak repair

    I'll give it a try. For me the bubbles are always on the pump, but the bubbles on the returns only happens for like a minute after tuning on the pump. So I figure I got a minute before the system stabilizes. Or am I missing something?
  7. PXL_20250511_193508853.jpg

    PXL_20250511_193508853.jpg

  8. PXL_20250511_193545858.jpg

    PXL_20250511_193545858.jpg

  9. PXL_20250511_193629625.jpg

    PXL_20250511_193629625.jpg

  10. PXL_20250511_193632597.jpg

    PXL_20250511_193632597.jpg

  11. PXL_20250511_193740907.jpg

    PXL_20250511_193740907.jpg

  12. S

    air leak repair

    okay understood on the suction side leak. I was trying to read up on how to detect where the leak is. So far I tried a smoke pen I have for attic airlfow investigation, but that didn't really show anything. I tried with the pump running, the pump startign and the pump off. I also saw online...
  13. S

    air leak repair

    Yup, that's my answers. I read the link you mentioned in your other post and wanted to make sure I understood. Air in the system is only from the suction side? So anything past the pump only will cause water leak? I dont think I get how that works. But I dont have any water leaks that I know...
  14. S

    air leak repair

    Tried to upload a video...
  15. S

    air leak repair

    Hard to tell if what I am looking at is air bubbles or just water being brought into the pump too fast? But yes it does look like large air bubbles in the pump basket, but its always looked that way, even when I've had no issues. So I may not know what I'm seeing but at least I know what it...
  16. PXL_20250507_183441384.jpg

    PXL_20250507_183441384.jpg

  17. PXL_20250507_183448326.jpg

    PXL_20250507_183448326.jpg

  18. PXL_20250507_183453257.jpg

    PXL_20250507_183453257.jpg

  19. PXL_20250507_183457930.jpg

    PXL_20250507_183457930.jpg

  20. PXL_20250507_183502330.jpg

    PXL_20250507_183502330.jpg

  21. PXL_20250507_183506366.jpg

    PXL_20250507_183506366.jpg

  22. PXL_20250507_183511112.jpg

    PXL_20250507_183511112.jpg

  23. PXL_20250507_183530635.jpg

    PXL_20250507_183530635.jpg

  24. PXL_20250507_183537097.jpg

    PXL_20250507_183537097.jpg

  25. PXL_20250507_183631313.jpg

    PXL_20250507_183631313.jpg

  26. S

    air leak repair

    Looks like I have an air leak in my system even though on my opening thread, opening 2025 I mentioned things went smoothly. I just checked and while everything looks good (except the psi) when the pump is running, once I stop the pump for a minute and then restart it, you can see air bubbles in...
  27. S

    opening 2025

    This is my 5th year opening up here in the NE and it went decently smooth, but still have one doubt. The pressure gauge says 4 PSI when the pump is on. Usually its around 13 psi at the beginning of the season and around 17 when the filter is dirty. This is for a 60 sq ft DE filter. Anyone know...
  28. S

    how to renovate 1 drain, 1 skimmer pool

    I have an old anthony and sylvan pool. I want to renovate it but I am not sure what to do about having 1 drain and 1 skimmer. The system works fine now with the existing 1.85 hp pump. I close it myself and can push a lot of air bubbles out of the main drain with a blower from the pump pad...
  29. S

    how much does it costs to replace all of the pool filter area?

    Thanks for that tip! I didn't know what you meant, but i looked it up and its when you can screw the pipes open and shut. Never knew that was an option, so I'm going to look at some equipment pad pictures to see what others have done.
  30. S

    how much does it costs to replace all of the pool filter area?

    awesome, thank you! @wireform /ajw22 I am in lower Westchester (I put in NYC because most people dont know where westchester is :). I was going to look at this last year, but time flies, so here we are and maybe I can get to this project this year. I also want to have gravel added to my pool...