Search results

  1. A

    Hayward H400 Problems

    Exactly, When I pulled the new one out I shut off the gas and held it in my hand only half of it glowed red. I didn't test the old one the same way just put it in but Im guessing the entire metal rod needs to glow?
  2. A

    Hayward H400 Problems

    I put the old igniter back in, fired right up????? go figure
  3. A

    Hayward H400 Problems

    Cleaned all orifices. no difference
  4. A

    Hayward H400 Problems

    No Pilot, just igniter, So I dont think the flame sensor is getting pre-heated, I haven't tried bleeding the gas because I can smell it when it tries to lite. The thing is 15 years old but I'm planning on selling the house when all this Crud blows over so I didn't want to spend 3000 if I dont...
  5. A

    Hayward H400 Problems

    Igniter glows cherry red, before and after I replaced it. I can hear the valve open and smell heavy propane smell. propane line above ground 6 feet from the tank, regulator is attached to the tank, I guess I need a pressure tester but again its really strange the transformer blew and the propane...
  6. A

    Hayward H400 Problems

    Never Lite's at all, I can smell the propane, I guess thats really my next step, I can hear the gas valve click, smell gas but no woosh and lite up. its attached to a full 500 gallon propane tank thats literally 6 feet away, I just find it really coincidental that the transformer went bad and...
  7. A

    Hayward H400 Problems

    Hello, Ive read every post on this site and more trying to get my heater working and hopefully someone has the answer here.... so here is the events 1. heater worked flawlessly for years 2. heater stops working , continually blows f2 fuse on power board once blower motor fires up 3. replace...