Thank you mknauss,
I'll continue.
How long this may take?
I have CC =0 and need to pass OCLT and get clear water. Looks like I should expect a long way to success:(
2nd day, at 11 am, I added bleach to make FC=20, but at 4 pm FC=22. Should drop due to sun, but has increased
3rd day, at 11 am, I added bleach to make FC=20, but at 3 pm FC=22. Should drop due to sun, but has increased
Strange behavior of FC.
I,m SLAMing my pool the third day.
I have strange readings of FC:
Day 1: 10 am - FC=4, CYA=50 - added bleach per PoolMath calculator up to FC=20
1 pm - FC=1, CYA=50 - added bleach
5 pm - FC=11, CYA=50 - added bleach
Day 2:
I've missed the...
Richard 320, mknauss and IceShadow,
Thank you for your help. I was lucky to find 10 gal of liquid bleach 8.25% in the Blain's Farm and Fleet (I forgot about it and searched in Menards, Lowes and Walmart).
I am going to start SLAMing tomorrow.
Thanks again(y)
Please help!
I have the same problem - no liquid bleach.
I can get cal-hypo 56.44%.
Can I use it for SLAM?
My current CH is 100ppm, pH+7.2, CYA=50, TA=70
Thank you very much.
Richard320!
Can I use for SLAM HTH 52023 Super Shock Treatment Swimming Pool Chlorine Cleaner
https://www.amazon.com/gp/product/B083X45KXN/ref=ppx_yo_dt_b_asin_title_o03_s00?ie=UTF8&psc=1
instead of the liquid bleach?
Now with COVID19, it is difficult to purchase 10 gal of bleach.
Thank you for...
I used concentrated bleach 6% Sodium Hydroxide from Meijer.
About pH: I tried to bring it to 7.5 (the upper range in recommended by TFP). At some reason, it did not change, now it is 7.22. I checked it with two methods.
The foam is gone. I believe it was due to air in the filter.
Now, my test...
Hello everybody - I need your help.
I am not very new to the pool maintenance, but I see this the first time.
I have opened the pool 2 days ago and found a lot of algae.
I've added 2 gallons of 6% bleach.
Yesterday, I've tested the water:
Salt -2500 ppm - added 20 lbs of salt
FC - 2 ppm - did...
Thank you JVTrain,
It's clear - I'll wait for the temperature to drop.
You mentioned: "close with polyquat and/or shock level FC". Does this mean that the shocking is not necessary with temperature below 60?
And my last question about TA level of 110 ppm. Do I need to lower it and how?
Thanks...
jblizzle,
A am still a bit confused.
1. You talk about 10 bottles, while the pool math calculator shows just 3 gal of bleach at SYA 70 that I have to add to get the shock level of 28 ppm FC.
2. I understand that the lower the temperature at closing and opening, the better. However, when I plug...
Hello,
I will be winterizing my above-ground pool first time this year.
I know that I have to disconnect all the equipment, bring the water down below the return line, clean pool and do all other routine I have previously done for the Bacquacil pool.
What I don't know - the chemistry of...
My today's test results:
Salt - 3200
FC - 6.5
CYA - 40 (increased from two days ago 20 ppm), on June 9 I added 126 oz of stabilizer. As I read, it may take a week for stabilizer to show correct level. So I am going to wait a couple more days.
TA - 120
pH - 7.5
CH - 175
My SWG has 50 % setting @...
Thank you guys for prompt and detailed response.
I have ordered TF-100 test kit.
umpalumpajay, I don't understand the part of your advise "you can start zero'ing in on the % and time you need to run it".
My AquaTrol has the knob called Desired Output with 1 to 100% scale and increment of 10%...