  1. nielsens2001

    Pressure higher after replacing grids

    Last time I cleaned the grids for my Hayward 4820 filter I noticed broken ribs. At the time, pressure was running 15 at 3050rpm after putting it back together. I ordered new grids (Pleatco) and just installed; pressure is currently 18. Should I have any concerns? Had assumed the pressure...
  2. nielsens2001

    New Mastertemp operating question

    Temperature between Heater & ET read same. Think I may try Erase EEPROM as last resort.
  3. nielsens2001

    New Mastertemp operating question

    Think next step is to reset back to factory settings (if possible), and set everything up just in case something was checked inadvertently.
  4. nielsens2001

    New Mastertemp operating question

    Have unplugged the spa-side controls, still no change. When Spa valve selected, no call for heat shown on the ET, however Heater still turns on. Makes me think there's something wrong w the board.
  5. nielsens2001

    New Mastertemp operating question

    Yes, it worked with the previous heater, Raypak
  6. nielsens2001

    New Mastertemp operating question

    No, it's been connected for a few years.
  7. nielsens2001

    New Mastertemp operating question

    Really odd it works for Pool, but not Spa. Here's the heater wiring into ET.
  8. EasyTouch.jpg

    EasyTouch.jpg

  9. nielsens2001

    New Mastertemp operating question

    @Jimrahbe & @Jim W thanks for your replies. Here are pics of the setup. With Spa selected either in EasyTouch or ScreenLogic, heater will not stop when temp set point is reached. It continues heating until 104F default temp on heater is reached. Pool settings, however work fine.
  10. Spa ScreenLogic.png

    Spa ScreenLogic.png

  11. Mastertemp Wiring.jpg

    Mastertemp Wiring.jpg

  12. Mastertemp 400.jpg

    Mastertemp 400.jpg

  13. nielsens2001

    New Mastertemp operating question

    I recently had a new Mastertemp heater installed. In pool mode I’m able to turn heater on, set setpoint temp on ScreenLogic and all works fine. However, in spa mode, I can turn heater on but no matter what I set in ScreenLogic including turning heater off it continues to run until the default...
  14. nielsens2001

    Wiring Pentair relay for GFCI

    I’d be adding another relay which it seems EasyTouch can handle up to 8, could I then obtain the power by adding another GFI?
  15. nielsens2001

    Wiring Pentair relay for GFCI

    Pics are now showing
  16. BD690F42-2664-424D-B765-02568C012EB5.jpeg

    BD690F42-2664-424D-B765-02568C012EB5.jpeg

  17. 30FB3D1F-B0EA-4F31-B26C-F9BBBF792F9F.jpeg

    30FB3D1F-B0EA-4F31-B26C-F9BBBF792F9F.jpeg

  18. 9D9E6006-C7C3-4020-835C-609FA40F55DD.jpeg

    9D9E6006-C7C3-4020-835C-609FA40F55DD.jpeg

  19. CC443232-8CF5-435A-8538-699DC429B99E.jpeg

    CC443232-8CF5-435A-8538-699DC429B99E.jpeg

  20. 0C704299-60AD-473E-929E-8B466A1ED75E.jpeg

    0C704299-60AD-473E-929E-8B466A1ED75E.jpeg

  21. nielsens2001

    Wiring Pentair relay for GFCI

    Have reattached, lmk if that’s any better. Thanks.
  22. nielsens2001

    Wiring Pentair relay for GFCI

    Here you go. Apologies for the wiring mess, a bit embarrassing.
  23. nielsens2001

    Wiring Pentair relay for GFCI

    Hope everyone is staying safe. Looking for some advice for wiring a GFCI outlet using an Easytouch relay enabling me to automate a small garden fountain. Last year, I upgraded to the Easytouch Upgrade from the Compool LX-100. After this, the existing GFCI the lights are wired into are only...
  24. 55900B19-EF99-4B4A-8EDC-DB8E7B7F621F.jpeg

    55900B19-EF99-4B4A-8EDC-DB8E7B7F621F.jpeg

  25. nielsens2001

    Pool & spa lights out of sync

    Investigated a bit more last evening. There are 2 junction boxes, for pool and spa and both appear to be 120V lights. In the spa function box, the pool lights are wired together with the spa light. From this box, the wires go out to the GFCI breaker and then 2 grey, 1 black and 1 white coming...
  26. nielsens2001

    Pool & spa lights out of sync

    Just upgraded my automation from LX-100 to Easy Touch upgrade. Fairly straight forward update for which everything appears to be work as before. Previously my pool & spa lights were out of sync and turn on together, have not been able to operate separately. Thought when upgrading this would...
  27. nielsens2001

    Pentair LX100 automatic system

    After looking at Jim's diagram and a bit of online research, it appears the controller that's gone bad is an earlier version of the Pentair iS4 remote. Have ordered a new one, will try this weekend and hopefully this solves the issue.
  28. nielsens2001

    Newbie Gunite Spa Jet Question

    Bought a house with an older gunite pool with attached spa. A few of the jet fittings are missing, so instead of just replacing I'm looking for advice about my options. Presently, there are 8 jets that each contain a Waterway 4" Venturi nozzle (217-3340). Is it possible to remove these and...
  29. nielsens2001

    Pentair LX100 automatic system

    Thanks, Jim. I’ll take a look when the weather clears up and post some photos.
  30. nielsens2001

    Pentair LX100 automatic system

    Recently purchased a home that has an older (14yr) pool & spa. It's controlled by a Pentair LX100 automatic system, however the spa side controller no longer works. Is there any option to fix this without putting updated automation in? A few other things on the priority list to address ahead...