Search results

  1. A

    Jandy LXi CHECK IGN CONTROL fault

    Well, Occam's Razor for the win. There was a previously unknown gas valve way over by the gas meter that somehow got turned off at some point in the last 5 months. I've put everything back the way it was including the original Fenwal and it fired right up! Thanks to @ajw22 @setsailsoon...
  2. A

    Jandy LXi CHECK IGN CONTROL fault

    I’m sure. It’s open.
  3. A

    Jandy LXi CHECK IGN CONTROL fault

    Embarrassed to admit that the sight window was actually easy. I thought I didn’t have one at all, but just needed to pop off that plastic piece. Anyways, the igniter glows until the valve is sent the signal to open (I get 26V at VAL) when it seems to fail and the igniter extinguishes. I see no...
  4. image.jpg

    image.jpg

  5. A

    Jandy LXi CHECK IGN CONTROL fault

    Yes, it was the Fenwal Igniter (35-665942-113) that I bought off eBay. I don’t smell gas, but if it would be faint I’m also not sure where I should be smelling (haha)...and it’s windy today. It’s an LXi250N. I’m not sure how anything could have gotten in the gas supply piping as everything...
  6. A

    Jandy LXi CHECK IGN CONTROL fault

    Correct, I have not run it since September. In the winter, we don't use our pool at all and rarely use our spa. I reviewed the manual, but don't see where it explains exactly what/how to inspect those areas. So, I took the bottom panel off to take a look in that area. It appeared clean. All...
  7. IMG_8157.jpg

    IMG_8157.jpg

  8. A

    Jandy LXi CHECK IGN CONTROL fault

    It's natural gas. I don't how to test the gas supply and pressure, but it worked fine ~last September.
  9. A

    Jandy LXi CHECK IGN CONTROL fault

    I'm getting a CHECK IGN CONTROL fault on my Jandy LXi. It will turn on and attempt to ignite a few times in 4 minutes, but it's unable to start. I have a voltmeter, so I've gone through the troubleshooting steps in this guide...
  10. A

    Wiring GFCI in EasyTouch 4

    I installed an EasyTouch 4 and want to make sure I wired my pool and spa lights correctly to my GFCI outlet. It works, but I have no way to test the GFI protection of the pool and spa light circuits. Hot: 15A breaker to GFCI outlet hot line - GFCI outlet hot load to Aux 2 (spa light) line with...