Search results

  1. drewhiggs

    Mastertemp 400 Control Board

    You nailed it James. The new membrane came in today and fixed the issue. Upon inspection, the off button has all kinds of dirt/corrosion on it. Thanks for the help!!!
  2. image.jpg

    image.jpg

  3. drewhiggs

    Mastertemp 400 Control Board

    I finally ordered the control board and installed it, but the display did not fix the issue. I started checking the fuse and line voltage and randomly it turned back on. I don't see any loose connections. After messing with it some more, it's still throwing the error ad0. After this error...
  4. drewhiggs

    Mastertemp 400 Control Board

    It’s almost 4 years old. Thanks for posting the link! I’ll check it out.
  5. drewhiggs

    Mastertemp 400 Control Board

    Well now it appears to be dead. Spa mode does not wake the heater up and the heater control panel is unresponsive. It looks like I need to start with a new control board for the heater.
  6. drewhiggs

    Mastertemp 400 Control Board

    I agree that I should never have to change the mode on the heater. The control panel should be making the change. The heater started performing this way back in may. Before this, I never touched the control panel on the heater.
  7. drewhiggs

    Mastertemp 400 Control Board

    Ok, I hope I can keep this from becoming confusing. Below are some troubleshooting steps. I manually changed the heater control panel to 104. Current spa temp: 94 I then moved the spa temp on the app to 95. The heater heated to 97 and turned off. Heater control panel shows 97 in spa mode...
  8. drewhiggs

    Mastertemp 400 Control Board

    It seems to keep resetting. I have to make this change every time I switch to spa mode. I just modified the heater control panel to 104. I’ll see if it cuts off we the controller temp or heats to 104.
  9. drewhiggs

    Mastertemp 400 Control Board

    Here you go.
  10. drewhiggs

    Mastertemp 400 Control Board

    I’m having issues with my mastertemp 400 control board. When I turn the heater on, from the app, the control board attempts to turn on, but then errors out and the display turns off. I can then manually turn on the heater from the control board interface, but it does not turn back on once the...
  11. drewhiggs

    Replace Pentair valve with Pentair actuator

    When I came home, I verified that it all worked as expected. This is how it should have been setup from the start! Thanks for the help!
  12. drewhiggs

    Replace Pentair valve with Pentair actuator

    Jim fixed me up! I was unaware of the "spillway" feature with screen logic and how it worked. All I need to do now is close the "Spa RT" valve, as Marty suggested, when I get home and I should be good to go.
  13. drewhiggs

    Replace Pentair valve with Pentair actuator

    Ah, ok. I will play with this and see if I can make it work.
  14. Capture.JPG

    Capture.JPG

  15. Capture.JPG

    Capture.JPG

  16. drewhiggs

    Replace Pentair valve with Pentair actuator

    This seems simple, but I'm not sure how to accomplish this without an actuator on the "Spa RT" valve. If I turn Actuator #1 manually (via the toggle switch), it drains all of the spa water into the pool. I have not seen what happens when I turn Actuator #2 manually.
  17. drewhiggs

    Replace Pentair valve with Pentair actuator

    Ok. Let me talk through this. By closing the spa return valve, you are suggesting I chlorinate the spa and pool independently via the SWG. Pool Mode for 6 hours (or whatever I decide it needs to be set to) Spa Mode for 30 minutes The only problem we run into is that when we use the spa...
  18. spa.JPG

    spa.JPG

  19. drewhiggs

    Replace Pentair valve with Pentair actuator

    I have 2 pumps, but 1 pump is for the water features (ledge bubbler and sheer descent), while the VS pump is for the pool and spa. Below is a current picture. When I select SPA, both valve actuator's turn. When in pool mode, all valves circled in blue are active. If I turn the valve labeled...
  20. Capture.JPG

    Capture.JPG

  21. drewhiggs

    Replace Pentair valve with Pentair actuator

    More than likely I do not know the correct terminology and I'm confusing the situation. I can give more information if needed.
  22. Capture.JPG

    Capture.JPG

  23. drewhiggs

    Replace Pentair valve with Pentair actuator

    No problem. Here is a picture of my equipment pad. When I turn the valve circled, I stop the return to the spa and the spillover stops. My thought is that I should be able to replace this valve with an actuator and stop the spillover. Does this sound right? These pictures are from when the...
  24. AEE3F30A-3BCE-47A4-9227-E586F2AB205B.jpeg

    AEE3F30A-3BCE-47A4-9227-E586F2AB205B.jpeg

  25. drewhiggs

    Replace Pentair valve with Pentair actuator

    So I'd like to replace a Pentair valve with a Pentair actuator, but I want to make sure it's as straight forward as I think it should be. Right now, I have a spa that spills over into the pool whenever the pool is filtering. I would like to replace a valve with an actuator so I can filter and...
  26. E0EB26B9-D1B2-4EA5-B520-5E691F391015.jpeg

    E0EB26B9-D1B2-4EA5-B520-5E691F391015.jpeg

    Pentair Actuator
  27. 0406C420-F6C2-47C2-B049-30D9D5CDB1F1.jpeg

    0406C420-F6C2-47C2-B049-30D9D5CDB1F1.jpeg

    Pentair valve
  28. drewhiggs

    The App, pump or cell run time?

    That is an awesome addition! I had no idea how much chlorine was being added before without this info! Just for informational purposes, the app keeps crashing when I play with numbers to see how it affects the chlorine output. If I change the swg % more than a couple of times, the app...
  29. drewhiggs

    The App, pump or cell run time?

    Ah, no worries. I saw "coming soon" in an earlier post then saw that pool math had an update yesterday, so I thought it was included. That will be a welcome addition, thanks for adding it!
  30. drewhiggs

    The App, pump or cell run time?

    @redth how are you adding the SWG as Chemical Additions? I've updated the app and I selected Chemical Additions, but I don't have the option for SWG. I've also turned on "Track SWG Cell %", so I'm not sure where to look next.