Search results

  1. edima302

    Pentair Intellichlor not turning on

    Hello. Noticed my chlorine generator did not turn on today so hoping someone can help me troubleshoot. There are no lights on when the pool is running. Attached some pics. Thx in advance.
  2. edima302

    Leak

    Hi everyone, Opened my pool and noticed a small (yet annoying) leak where the pvc pipe meets the flow valve. Is there a way to stop it without cutting the pipe? Perhaps use a sealer ? Thanks
  3. edima302

    Jandy Actuator Valve

    Hi all, I just replaced my Jandy Actuator (model 2444) and am having trouble getting the gears to line up. I have the switch set to the On 1 position and the valve is turning as far right as possible while on pool mode. How do I get it to stop at a 90 degree angle so that the spa runs properly...
  4. edima302

    Hot tub (spill over type) drains when pump is off

    Hello everyone, quick question. For some reason my hot tub has been draining into my pool on a daily basis when the pump turns off. Don't think I recall seeing this in prior years other than perhaps when the temps drop ? Not sure that makes sense but anyhow it seems to be a daily thing now...
  5. edima302

    Pool Opening

    Hi all, Opened my pool and for the 2nd time in 2 yrs have noticed that whatever my pool guy uses when he closed it, made quite a mess at the bottom of my pool. I ran my Polaris for the better part of the day only to clean out from the bag (6 times!) what looks like fine crystal white stuff...
  6. edima302

    Jandy AquaLink RS one touch control system

    Hi everyone, Hoping to get some help with my one touch Jandy Aqualink control system. We opened the pool but the indoor controller does not work so I have the pool running on service mode. The LCD screen is blank and the only thing I am getting is an amber (red/yellow) light at the bottom right...
  7. edima302

    Leak - possible return line ?

    Hello everyone. It looks like I have a possible leak. When I turn on the filter (pool mode) water starts to appear on my pavers. The issue is above a return line to the right of the skimmer in the shallow end. When I turn the valve to spa mode the wet spot drys up which tells me it’s not...
  8. edima302

    Raypak 406A Gas Heater - clock/fireman switch

    Need help with my Raypak gas heater. It is not lighting and am getting a clock/fireman switch message on the front panel. The pool and equipment are controlled by a Aqualink RS control panel and the heater doesn’t work in Auto or when I switch it to Service Mode. Anyone know what the issue can...
  9. edima302

    Plaster renovation

    I live in Marlboro New Jersey and need to find a good plaster guy to redo my inground pool and give the pool a makeover with new coping and stone (I have a spa that sits above with waterfall that pours in pool). Any suggestions?