  1. C

    Aqua Rite salt reading not accurate

    Rob, I have a 22,000 gal pool. I just dumped 520lbs of salt in the pool. I'm fairly positive that the cell needs some sort of assessment when the salt reading went down from 2600 pre-520lbs to 2500 post-520lbs. The strips show I'm up over 3200ppm which by all calculations is closer to the...
  2. C

    Aqua Rite salt reading not accurate

    I don't live near a Leslies (never herad of it actually). I live in Fayetteville, NC with not much pool support around here. The local pool supply places kind of bang on the SWGs because they want to sell their overpriced chemicals. I will clean it with MA solution and if that doesn't work, I...
  3. C

    Aqua Rite salt reading not accurate

    By testing, I assume it's going to require me sending it in to the manufacturer?
  4. C

    Aqua Rite salt reading not accurate

    Water temp is 80 degrees F. Salt was added 2 days ago. Cell is 7 years old.
  5. C

    Aqua Rite salt reading not accurate

    The instant salt reading is 2500. When I initially started this and put in 13 x 40lb bags (as required from my 22,000 gal pool) the reading was 2600 so I'm left to assume that the test strips stating 3200ppm are correct. To continue adding bags of salt just because the system thinks there's...
  6. C

    Aqua Rite salt reading not accurate

    OK, I'm ready to try anything. How do I recalibrate since the salt level is reading 2500 ppm since the low salt warning is preventing chlorine generation as the test strips showing I have 3200 ppm in the pool?
  7. C

    Aqua Rite salt reading not accurate

    Jason, Understand all. Pool temp is 78. The problem with the reading of 2600 is that the "low salt" warning light is on and the system won't generate because of it. Do you know of a work around?
  8. C

    Aqua Rite salt reading not accurate

    This is an excellent site with a great deal of useful, relevant, and accurate information...thanks so much for keeping it going. My issue...my Aqua Rite T-Cell-15 is reporting only 2500 ppm while my salt test strips show I actually have 3200 ppm. I added salt yesterday while the reading on the...
  9. C

    General Salt Setup Question

    How long should it take for the initial addition of salt before it's cycled through and the test strips will be accurate?
  10. C

    Flow Switch for Goldline SWG

    Does the flow switch only monitor water flow and temperature or does it also determine the salt ppm? I'm having issues with the salt reading on the readout on my Aqua Rite T-Cell-15 not being accurate and was wondering if that was a flow switch function. 22,000 gal, vinyl, inground, haywood...