Search results

  1. M

    Zodiac new cell broken?

    Thanks, Malcolm. The control panel just works 'normal' - all lights work as they should (so the lights "no flow" & "add salt" are both off/not lit). Green are the lights that indicate the chlorine level/output. It all looks normal (hence I thought the cell was the problem!), but still no...
  2. M

    No power to cell (zodiac LM-15) !?!

    Just following up on another post I put out. So my Zodiac cell is not producing chlorine. I have checked the wires leading into the cell with a volt meter, and indeed, no electricity runs from power unit to cell. What can this be? Fuse blown? Anyway I could check/see the problem & fix myself...
  3. M

    Zodiac new cell broken?

    Dear Spishex, You were RIGHT! No charge from zodiac clearwater power unit! What could be the problem? Fuse blown? Could we fix it ourselves? Thanks! Merel
  4. M

    Zodiac new cell broken?

    It may be an issue with the power board or the transformer. All the controls work properly, correct? Yes, all functions work fine, no problems there. Maybe it's the lead towards the cell? Will try the volt meter soon. THANKS AGAIN! Merel
  5. M

    Zodiac new cell broken?

    You can normally see bubbles in one of those units if the cell is generating. Is the control allowing you to set the output all the way up? If you have a volt meter handy, check to see that there's power getting to the cell. Spishex, Thanks! My husband already suspected something like this...
  6. M

    Zodiac new cell broken?

    Please can anyone give me advice- I am completely lost! We have a saltwater pool. Since 6 weeks we all of a sudden have no FC reading.. I thought it may be the cell which needed replacing (was installed 6 yrs ago...). Bought a new one (Zodiac clearwater LT-15). Installed it. Nothing! Water...